𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Miniaturised sample preparation of fatty foodstuffs for the determination of polychlorinated biphenyls

✍ Scribed by Juan-José Ramos; M.-José González; Lourdes Ramos


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
420 KB
Volume
27
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A miniaturised analytical method allowing the exhaustive extraction of environmentally relevant polychlorinated biphenyls (PCBs) from fatty foodstuffs and the purification of the extracts in a single step has been developed. After dispersion of the freeze dried sample on silica modified with 44% (w/w) of sulphuric acid, the mixture was packed in a glass column on top of a multilayer silica column used for removal of the lipids and biogenic co‐extracted material. Using this arrangement, a complete sample preparation can be accomplished by two successive 10 min static extractions with hexane followed by a brief dynamic step to ensure purging of the sample and sorbents. The analytical method showed a satisfactory performance, with recoveries of the endogenous PCBs studied in the 81–134% range of those found using a more conventional off‐line procedure, even though as small an amount of sample as 0.1 g was used. Detection limits by gas chromatography with micro‐electron capture detection (GC–ECD) were in all cases lower than 0.3 ng/g sample (freeze dried basis) and the repeatability of the complete analytical procedure better than 14% (except for PCB 167). When combined with GC and ion trap detection in the tandem mass spectrometry mode, the miniaturised method has been proved to be a valuable alternative to the more expensive high resolution mass spectrometry for fast screening of PCBs 77, 126, and 169, even if these congeners were not isolated from the bulk of PCBs.


📜 SIMILAR VOLUMES


Headspace solid-phase microextraction fo
✍ Maria Llompart; Ken Li; Merv Fingas 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 162 KB 👁 2 views

A headspace solid-phase microextraction HSSPME method has been Ž . developed for the quantification of polychlorinated biphenyls PCBs in soils and sediments. In this study polydimethylsiloxane fibers with a 100 m thickness were used. Parameters affecting the extension of the adsorption process were

Procedure for the determination of total
✍ John K. Sanders 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 166 KB 👁 1 views

A Hewlett-Packard PrepStation/HPLC system has been used to automatically process samples for the determination of total iodine. The protocol for sample preparation consists of sequentially hydrolyzing the sample, oxidizing any organic/inorganic iodo-compounds to iodate, and reduction of iodate to io