𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microsequence analysis of electroblotted proteins: II. Comparison of sequence performance on different types of PVDF membranes

✍ Scribed by David F. Reim; David W. Speicher


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
594 KB
Volume
207
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


The influence of different types of polyvinylidene difluoride (PVDF) membranes on gas phase sequence performance has been evaluated. These PVDF membranes have been classified as either high retention (Trans-Blot and ProBlott) or low retention membranes (Immobilon-P) based on their ability to bind proteins during electroblotting from gels. Initial yields, repetitive yields, and extraction efficiency of the anilinothiazolinone amino acid derivatives have been compared for several standard proteins that have been either electroblotted or loaded onto PVDF membranes by direct adsorption. These results show that the major differences in initial sequence yields between membranes arise from differences in the amount of protein actually transferred to the membrane rather than sequencer-related factors. In contrast to several previous observations from other laboratories, more tightly bound proteins do not sequence with lower initial yields and initial yields are not affected by the ratio of surface area to protein. The stronger binding on high retention PVDF membranes does not adversely affect recoveries of difficult to extract, or very hydrophobic, amino acid derivatives. Several amino acids, especially tryptophan, are actually recovered in dramatically higher yield on high retention membranes compared with either Immobilon or glass filters. At the same time, the protein and peptide binding properties of high retention membranes will frequently improve the repetitive yield by minimizing sample extraction during the sequencer cycle. Stronger protein binding together with improved electroblotting yields offer substantially improved sequence performance when high retention PVDF membranes are used.


πŸ“œ SIMILAR VOLUMES


High-Sensitivity Gas Phase Sequence Anal
✍ D.F. Reim; D.W. Speicher πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 734 KB

An optimized sequencer program with a cycle time of \(38 \mathrm{~min}\) which is specifically tailored for analysis using polyvinylidene difluoride (PVDF) membranes has been developed. The program was developed using a pulsed liquid-phase instrument which was converted to gasphase acid delivery. Ga

Microsequence analysis of peptides and p
✍ David Hawke; Pau-Miau Yuan; John E. Shively πŸ“‚ Article πŸ“… 1982 πŸ› Elsevier Science 🌐 English βš– 716 KB

A comparison of the separation of the common phenylthiohydantoin derivatives of amino acids on DuPont octadecylsilane with that obtained with Ultrasphere octadecylsilane supports is given together with the effect of acetate, phosphate, and trifluoroacetate buffers in the elution solvents. An importa

Effects of hepatitis C virus on suppress
✍ StΓ©phanie Pascarella; Sophie ClΓ©ment; KΓ©vin Guilloux; StΓ©phanie Conzelmann; Fran πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 872 KB

## Abstract Glucose metabolism disturbances, including insulin resistance and type 2 diabetes, are frequent and important cofactors of hepatitis C. Increasing epidemiological and experimental data suggest that all major genotypes of hepatitis C virus (HCV), albeit to a different extent, cause insul