Abstract

In the present study, samples of lotrafilcon A, balafilcon A, and galyfilcon A contact lenses were observed by atomic force microscopy (AFM) in tapping mode at areas ranging from 0.25 to 400 μm^2^. Mean roughness (Ra), root‐mean‐square roughness (Rms) and maximum roughness (Rmax) in nanometers were obtained for the three lens materials at different magnifications. The three contact lenses showed significantly different surface topography. However, roughness values were dependent of the surface area to be analyzed. For a 1 μm^2^ area, statistics revealed a significantly more irregular surface of balafilcon A (Ra = 6.44 nm; Rms = 8.30 nm; Rmax = 96.82 nm) compared with lotrafilcon A (Ra = 2.40 nm; Rms = 3.19 nm; Rmax = 40.89 nm) and galyfilcon A (Ra = 1.40 nm; Rms = 1.79 nm; Rmax = 15.33 nm). Ra and Rms were the most consistent parameters, with Rmax presenting more variability for larger surface areas. The higher roughness of balafilcon A is attributed to the plasma oxidation treatment used to improve wettability. Conversely, galyfilcon A displays a smoother surface. Present observations could have implications in clinical aspects of siloxane–hydrogel contact lens wear such as lens spoliation, resistance to bacterial adhesion, or mechanical interaction with the ocular surface. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006


📜 SIMILAR VOLUMES


Microscopic observations of superficial
✍ José M. González-Méijome; Antonio López-Alemany; José B. Almeida; Manuel A. Para 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 251 KB

## Abstract The purpose of this study was to analyze three commercial siloxane‐hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observ

Comparative study of silicone-hydrogel c
✍ M. Lira; L. Santos; J. Azeredo; E. Yebra-Pimentel; M. Elisabete C. D. Real Olive 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 408 KB

## Abstract __Purpose:__ The aim of this study was to analyze surface changes of three silicone‐hydrogel contact lenses after daily wear. The lenses used in this study were balafilcon A, lotrafilcon B (both surface‐treated), and galyfilcon A (non surface‐treated). __Methods:__ To understand how and