𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microscopic magnetic resonance elastography (μMRE)

✍ Scribed by Shadi F. Othman; Huihui Xu; Thomas J. Royston; Richard L. Magin


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
843 KB
Volume
54
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Magnetic resonance elastography (MRE) was extended to the microscopic scale to image low‐frequency acoustic shear waves (typically less than 1 kHz) in soft gels and soft biological tissues with high spatial resolution (34 μm × 34 μm × 500 μm). Microscopic MRE (μMRE) was applied to agarose gel phantoms, frog oocytes, and tissue‐engineered adipogenic and osteogenic constructs. Analysis of the low‐amplitude shear wave pattern in the samples allowed the material stiffness and viscous loss properties (complex shear stiffness) to be identified with high spatial resolution. μMRE experiments were conducted at 11.74 T in a 56‐mm vertical bore magnet with a 10 mm diameter × 75 mm length cylindrical space available for the elastography imaging system. The acoustic signals were generated at 550–585 Hz using a piezoelectric transducer and high capacitive loading amplifier. Shear wave motion was applied in synchrony with the MR pulse sequence. The field of view (FOV) ranged from 4 to 14 mm for a typical slice thickness of 0.5 mm. Increasing the agarose gel concentration resulted in an increase in shear elasticity and shear viscosity. Shear wave motion propagated through the frog oocyte nucleus, enabling the measurement of its shear stiffness, and in vitro shear wave images displayed contrast between adipogenic and osteogenic tissue‐engineered constructs. Further development of μMRE should enable its use in characterizing stiffer materials (e.g., polymers, composites, articular cartilage) and assessing with high resolution the mechanical properties of developing tissues. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Magnetic resonance elastography: A revie
✍ Yogesh K. Mariappan; Kevin J. Glaser; Richard L. Ehman 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 835 KB

## Abstract Magnetic resonance elastography (MRE) is a rapidly developing technology for quantitatively assessing the mechanical properties of tissue. The technology can be considered to be an imaging‐based counterpart to palpation, commonly used by physicians to diagnose and characterize diseases.

Magnetic resonance elastography of skele
✍ M. Alex Dresner; Gregory H. Rose; Phillip J. Rossman; Raja Muthupillai; Armando 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 498 KB 👁 1 views
Needle shear wave driver for magnetic re
✍ Q.C.C. Chan; G. Li; R.L. Ehman; R.C. Grimm; R. Li; E.S. Yang 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 343 KB

## Abstract Magnetic resonance elastography (MRE) is capable of quantitatively depicting the mechanical properties of tissues in vivo. In contrast to mechanical excitation at the surface of the tissue, the method proposed in this study describes shear waves produced by an inserted needle. The resul

Transurethral prostate magnetic resonanc
✍ Arvin Arani; Donald Plewes; Rajiv Chopra 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 618 KB

## Abstract Tissue stiffness is known to undergo alterations when affected by prostate cancer and may serve as an indicator of the disease. Stiffness measurements can be made with magnetic resonance elastography performed using a transurethral actuator to generate shear waves in the prostate gland.

Cross-validation of magnetic resonance e
✍ Jennifer Oudry; Jun Chen; Kevin J. Glaser; Véronique Miette; Laurent Sandrin; Ri 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 367 KB

## Abstract ## Purpose: To cross‐validate two recent noninvasive elastographic techniques, ultrasound‐based transient elastography (UTE) and magnetic resonance elastography (MRE). As potential alternatives to liver biopsy, UTE and MRE are undergoing clinical investigations for liver fibrosis diagn