𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microscale ion chromatography for sample-limited systems

✍ Scribed by Remcho, V. T. ;Wilson, W. H. ;McNair, Harold M.


Publisher
John Wiley and Sons
Year
1990
Tongue
English
Weight
262 KB
Volume
13
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


An alternative gas sample introduction s
✍ Hilling, P. A. ;Dawes, P. A. ;David, W. πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 402 KB πŸ‘ 1 views

I 0733r I 0734 acids. Methanol containing 0.001 M tetramethylammonium hydroxide (J. T. Baker, Phillipsburg, NJ) served as the modifier. A kit of PTH amino acids was obtained from Sigma Chemical Co. (St. Louis, MO). ## 3 Results and Discussion Twenty-four PTH-amino acids have been rapidly and effic

A sampling system using sample vials for
✍ Evrard, E. ;Mercier, M. ;Bal, M. πŸ“‚ Article πŸ“… 1979 πŸ› John Wiley and Sons 🌐 English βš– 402 KB πŸ‘ 1 views

## Abstract A novel sampling system for isothermal capillary gas chromatography of medium‐ or low‐volatility mixtures is described and test results are reported using flame ionization detection. The system features a loading and positioning chamber for glass vials which can carry a dilute sample in

Procedure for the determination of total
✍ John K. Sanders πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 166 KB πŸ‘ 1 views

A Hewlett-Packard PrepStation/HPLC system has been used to automatically process samples for the determination of total iodine. The protocol for sample preparation consists of sequentially hydrolyzing the sample, oxidizing any organic/inorganic iodo-compounds to iodate, and reduction of iodate to io

Determination of Trace-Level Anions in H
✍ Yan Liu; Edward Kaiser; Nebojsa Avdalovic πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 68 KB

The use of the hydroxide eluents generated on-line by an automated hydroxide eluent generator system was compared with the use of hydroxide eluents prepared off-line in the ion chromatographic determination of trace inorganic and organic anions in high-purity water samples. The use of the hydroxide

Special cooling system for the on-column
✍ Galli, M. ;Trestianu, S. ;Grob, K. πŸ“‚ Article πŸ“… 1979 πŸ› John Wiley and Sons 🌐 English βš– 346 KB πŸ‘ 2 views

## Abstract On‐column injection into a hot gas chromatograph oven involves the danger that the bottom part of the needle is warmed up above the boiling point of the solvent in the sample. Consequently parts of the sample are evaporated out of the needle instead of being introduced as a liquid into