Implementation of digital methods to increase and maintain data-conversion accuracy in real environment can be regarded as an important direction to improve quality of experimental research. Microprocessors availability allows to realize these methods. The paper describes a new algorithm of calibration and digital correction of high-accuracy data-converters and gives examples of its implementation in experimental devices.

1. Infroduction

values and shapes of currents and voltages. The BD-algorithm of calibration was worked out to Data converters are important components of provide high accuracy of DAC in operating condimeasuring and control systems in experiments and tions [3J. It is meant for precise determination the provide an interface of computers and experimen-DAC transfer functions. The DAC output signal tal installations. Their accuracy determines the A(x) is a joint (U) of certain bit weights Ak quality of a research to a great extent. High re-corresponding to the input code x. At first, let us quirements of modern experimental physics to the assume that the superposition principle satisfies accuracy and reliable stability of converters make the required accuracy, so the output signal value solution of some problems connected with the can be represented by an arithmetic sum of the bit operative metrological maintenance in real en-weights eigenvalues (BW): vironment quite urgent.


πŸ“œ SIMILAR VOLUMES


The accuracy of ultrasound evaluation of
✍ Magann, Everett F.; Perry, Kenneth G.; Chauhan, Suneet P.; Anfanger, Phyllis J.; πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 236 KB πŸ‘ 2 views

The objective of this study was to evaluate the effect of operator experience and ultrasound interpretation technique on the accuracy of ultrasound estimates of amniotic fluid volume. Ultrasound evaluation was carried out by an obstetric resident, a nurse sonographer, a maternal-fetal medicine fello

Differential health effects of written p
✍ Luigi Solano; Luisa Pepe; Valentina Donati; Stefano Persichetti; Guido Laudani; πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 124 KB

## Abstract The aim of this study was to assess the effects of the writing technique on postoperative course in interaction with different levels of risk. Participants were 40 urologic inpatients waiting to undergo transurethral resection of the prostate, with different levels of surgical risk as a