𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microindentation for in vivo measurement of bone tissue mechanical properties in humans

✍ Scribed by Adolfo Diez-Perez; Roberto Güerri; Xavier Nogues; Enric Cáceres; Maria Jesus Peña; Leonardo Mellibovsky; Connor Randall; Daniel Bridges; James C Weaver; Alexander Proctor; Davis Brimer; Kurt J Koester; Robert O Ritchie; Paul K Hansma


Publisher
American Society for Bone and Mineral Research
Year
2010
Tongue
English
Weight
358 KB
Volume
25
Category
Article
ISSN
0884-0431

No coin nor oath required. For personal study only.

✦ Synopsis


Bone tissue mechanical properties are deemed a key component of bone strength, but their assessment requires invasive procedures. Here we validate a new instrument, a reference point indentation (RPI) instrument, for measuring these tissue properties in vivo. The RPI instrument performs bone microindentation testing (BMT) by inserting a probe assembly through the skin covering the tibia and, after displacing periosteum, applying 20 indentation cycles at 2 Hz each with a maximum force of 11 N. We assessed 27 women with osteoporosis-related fractures and 8 controls of comparable ages. Measured total indentation distance (46.0 ± 14 versus 31.7 ± 3.3 µm, p = .008) and indentation distance increase (18.1 ± 5.6 versus 12.3 ± 2.9 µm, p = .008) were significantly greater in fracture patients than in controls. Areas under the receiver operating characteristic (ROC) curve for the two measurements were 93.1% (95% confidence interval [CI] 83.1–100) and 90.3% (95% CI 73.2–100), respectively. Interobserver coefficient of variation ranged from 8.7% to 15.5%, and the procedure was well tolerated. In a separate study of cadaveric human bone samples (n = 5), crack growth toughness and indentation distance increase correlated (r = –0.9036, p = .018), and scanning electron microscope images of cracks induced by indentation and by experimental fractures were similar. We conclude that BMT, by inducing microscopic fractures, directly measures bone mechanical properties at the tissue level. The technique is feasible for use in clinics with good reproducibility. It discriminates precisely between patients with and without fragility fracture and may provide clinicians and researchers with a direct in vivo measurement of bone tissue resistance to fracture. © 2010 American Society for Bone and Mineral Research.


📜 SIMILAR VOLUMES


Gender-specific in vivo measurement of t
✍ Gladys N.L. Onambélé; Katherine Burgess; Stephen J. Pearson 📂 Article 📅 2007 🏛 Elsevier Science 🌐 English ⚖ 151 KB

## Abstract Human patellar tendon stress (σ), strain (ε), stiffness (__K__), and tensile or Young's modulus (__E__), are determined in vivo through voluntary isometric contractions monitored with B‐mode ultrasonography. The limitations in previous studies are: (1) they have generally not accounted

Erratum: Gender-specific in vivo measure
✍ Gladys N.L. Onambélé; Katherine Burgess; Stephen J. Pearson 📂 Article 📅 2007 🏛 Elsevier Science 🌐 English ⚖ 57 KB

## Abstract The address for the corresponding author, Gladys N.L. Onambélé, should read: Department of Exercise & Sport Sciences, Manchester Metropolitan University, Hassall Road, Alsager ST7 2HL, United Kingdom. The article to which this Erratum refers was published in this issue on pages 1635–16

In vivo bone biocompatibility and degrad
✍ Amit S. Mistry; Quynh P. Pham; Corinne Schouten; Tiffany Yeh; Elizabeth M. Chris 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 474 KB

## Abstract The objective of this study was to determine how the incorporation of surface‐modified alumoxane nanoparticles into a biodegradable fumarate‐based polymer affects __in vivo__ bone biocompatibility (characterized by direct bone contact and bone ingrowth) and __in vivo__ degradability. Po

In vivo biocompatibility and mechanical
✍ Zhang, X. S. ;Revell, P. A. ;Evans, S. L. ;Tuke, M. A. ;Gregson, P. J. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 499 KB 👁 1 views

Two epoxy materials with or without adhesively bonded hydroxyapatite (HA) coatings were studied for their biocompatibility and mechanical pushout strength using in vivo implantation in the rabbit lower femur for a duration of 10 days to 6 months. Both were two-part epoxies cured at room temperature

The role of collagen in the declining me
✍ Zioupos, P. ;Currey, J. D. ;Hamer, A. J. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 238 KB 👁 3 views

The importance of the mechanical role of collagen in bone is becoming increasingly more clear as evidence mounts on the detrimental effects of altered collagen on the mechanical properties of bone. We previously examined a set of mechanical properties (material stiffness, strength, and toughness) of