## Abstract The lymphatic system plays an essential physiological role in homeostasis, interstitial fluid composition, and immunity while impaired lymphatic function has been implicated in a number of pathological conditions, including arthritis and delayed wound healing. This study investigated ly
Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone
β Scribed by S. S. Huja; T. R. Katona; B. K. Moore; W. E. Roberts
- Publisher
- Elsevier Science
- Year
- 1998
- Tongue
- English
- Weight
- 818 KB
- Volume
- 16
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Limited information is available on the mechanical properties of the rapidly remodeling bone that surrounds endosseous implants. Fifteen implant-bone blocks were obtained from the mid-femoral diaphyses of three mature male hounds 12 weeks after placement of the implants. To evaluate the microhardness and cortical anisotropy of bone, the implants were sectioned along their long axes. In this process, the femurs were sectioned transversely. Knoop microhardness measurements (HK) were made with a 50 g force on cortical bone and a 25 g force on periosteal callus, endocortical callus, and circumferential lamellar bone. The long diagonal of the indenter was placed parallel to the implant (in the radial bone direction). Measurements were made in cortical bone at 200, 400, 600, 800, 1,000, 1,500, 2,000, and 2,500 microm from both sides of the implant. To detect cortical anisotropy in the radial compared with the tangential direction, a second set of indentations was made perpendicular to the first. Microhardness of periosteal callus and endocortical callus and anisotropy of circumferential lamellar bone near the endocortical surfaces of the femur were also evaluated. Repeated measures analysis of variance showed significantly (p < 0.05) lower microhardness values (30.6 +/- 0.8 HK [mean +/- SEM]) for cortical bone at 200 microm than at any other location (range: 40.3-46.6 HK). Microhardness anisotropy was not detected in cortical bone. Furthermore, within 200 microm of the implant surface, the Knoop microhardness values were significantly lower for periosteal and endocortical calluses than for cortical bone. These data provide information about the mechanical properties of bone adjacent to endosseous implants at a microstructural level. The results are consistent with the high rate of remodeling seen adjacent to endosseous implants at 12 weeks after implantation.
π SIMILAR VOLUMES
Methods for evaluating the interface between bone and an experimental dental implant have been analyzed. The material studied was a titanium implant coated with a mixture of alumina and titanium dioxide by means of a plasma-jet system with the dog as the animal model. The evaluations were made on tw
Rods of three bioactive materials, apatite/wollastonite glass ceramic (AW-GC), bioactive glass (BG), and dense slip-cast hydroxyapatite (HA), were implanted in the femora of 23 Wistar rats for periods of 1-4 weeks. The samples were harvested following vascular perfusion fixation and the femora freez
## Abstract We evaluated bone microhardness at the interface with hydroxyapatiteβcoated stainlessβsteel pins used in an external fracture fixation system. Pins were transversally inserted into the diaphyses of sheep tibiae and were loaded in for 6 weeks. Uncoated pins were implanted as controls. Mi
The bone-implant interface formed in a canine distal femur was examined by means of a Raman microprobe using an implant model designed to test calcium phosphate surface coatings. By using the 960 cm-' band of calcium phosphate to characterize the interface and adjacent mineral, we ob-tained spatial
The effect of coating resorption on bone apposition and attachment strength to resorbable hydroxyapatite (HA), nonresorbable HA-coated, and uncoated rough titanium implants was evaluated in interference-and noninterferencefit (gap of 2-3 mm) surgical models 2, 4, and 12 weeks postoperatively. Interf