✦ Synopsis


Abstract

A new microflow system was designed and developed for electrochemical measurements. The electrochemical electrodes prepared using thick film technology were used in this arrangement. Results of various measurements such as simple amperometric measurement on the example of H~2~O~2~ detection, measurement with glucose oxidase (GOx) biosensor, soluble enzyme activity measurement etc. carried out using this system are reported. It was observed that the sensitivity and reproducibility of the electrochemical measurements is improved significantly. The new device performance was proved on H~2~O~2~ detection, activity of GOx measurement and heavy metals detection (measured concentration range: H~2~O~2~ 10^−9^ to 10^−1^ M, glucose 10^−6^ to 10^−2^ M, activity of GOx 10^−1^ to 10^2^ IU, heavy metals (Cu, Pb) 10^−4^ to 10^−3^ M). The microflow insert greatly reduces the overall size of the electrolyte vessel and measurements with sample quantity as low as 2 mL can be accomplished.


📜 SIMILAR VOLUMES


Sensitivity and reproducibility of indir
✍ Cecilia Karlsson; Theodore Lystig; Marianne Hartford; Björn Carlsson 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 101 KB

## Abstract The aim of this study was to assess indirect calorimetry measurement of resting metabolic rate (RMR) with respect to sensitivity and reproducibility in a human study population suitable for early clinical studies to evaluate new anti‐obesity candidate drugs. Twenty‐four overweight, but

Reproducibility and comparability of ins
✍ Hovorka, R.; Bannister, P.; Eckland, D.J.A.; Halliday, D.; Murley, D.N.; Rees, S 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 154 KB 👁 1 views

We have investigated the reproducibility of (1) insulin sensitivity (S\*I) and glucose effectiveness (S\*G) as measured by the stable-label (one compartment) minimal model, and (2) insulin sensitivity (S\*Ib), plasma clearance rate (PCR), basal hepatic output (HGOb), and total hepatic glucose output

Three-dimensional surface imaging for cl
✍ Elliot T. Weiss; Ori Barzilai; Lori Brightman; Anne Chapas; Elizabeth Hale; Juli 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 156 KB

Background and Objectives: Numerous body contouring and laser-assisted liposuction devices have recently obtained or are seeking FDA clearance, and assessment of efficacy of these devices is largely based upon qualitative comparisons of before and after photographs and measurable changes in patient