𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Microbiological profile of crude oil in storage tanks

✍ Scribed by Harrison Ifeanyichukwu Atagana


Publisher
Springer
Year
1996
Tongue
English
Weight
417 KB
Volume
41
Category
Article
ISSN
0167-6369

No coin nor oath required. For personal study only.

✦ Synopsis


Microbiological quality of crude oil storage tanks was determined. The samples were taken from crude oil storage tanks in three stations, at Ughelli, Escravos and Forcados tank farms in the Delta State of Nigeria. Two tanks were sampled at each station with samples collected from three levels of the tank, namely the oil layer, oil water interface, and effluent layer. Samples from the inner walls and bottom sediment of the only empty tank in Ughelli during the study were also taken. The total heterotrophic count of bacteria and total fungal count were obtained by plating samples on nutrient agar and sabouraud's glucose agar respectively and incubated for 14 days at 28 °C±2 °C. Oilutilizing bacteria and fungi were isolated on oil agar using fungizone and antibiotics to inhibit fungal and bacterial growth respectively. Pure cultures of bacteria and fungi were prepared on nutrient agar and sabouraud's glucose agar respectively at 28 °C±2 °C for 4 days. Isolates were identified using approved standard methods. Three bacterial genera, Pseudomonas, Proteus and Bacillus, and one actinomycete, Actinomyces and two fungal genera, Penicillium and Cunninghamella, were isolated. Pseudomonas was dominant among the bacteria (41.62%) and Penicillium dominant among the fungi (94%). It was also found that the total microbial load of the effluent layer was higher than that of the oil layer.


📜 SIMILAR VOLUMES


Corrosion inhibition of steel in crude o
✍ M. A. Khalifa; M. El-Batouti; F. Mahgoub; A. Bakr Aknish 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 German ⚖ 334 KB

## Abstract The corrosion behavior of steel in water from certain oil fields with various organic inhibitors was studied by applying potentiodynamic technique at pH 5.9. The inhibitors which were used include 2‐methylbenzimidazole (I), 2‐mercaptobenzimidazole (II), 2‐mercapto‐5‐methylbenzimidazole

Cathodic protection of cargo/ballast tan
✍ C. de Waard; W. Posch 📂 Article 📅 1972 🏛 John Wiley and Sons 🌐 German ⚖ 400 KB

## Abstract Unless a special protection is provided pitting corrosion may occur on top and at the bottom of ballast tanks. Usually a partial coating (horizontal areas) is used in connection with cathodic protection by sacrificial anodes. More than two years' observation of coated and uncoated, cath