## Abstract Previously published fast spinβecho (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be
Method for efficient fast spin echo Dixon imaging
β Scribed by Jingfei Ma; Sanjay K. Singh; Ashok J. Kumar; Norman E. Leeds; Lyle D. Broemeling
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 385 KB
- Volume
- 48
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
In order to satisfy the Carr-Purcell-Meiboom-Gill (CPMG) condition, echo shift as dictated in fast-spin-echo (FSE)-based Dixon imaging was previously achieved by applying a time shift to the readout gradient and the data acquisition window. Accordingly, interecho spacing is increased, which entails increased image blurring and, in multislice imaging, a significant reduction in the slice coverage for a given imaging time. In this work, a new method is developed by which the echo shift is induced by "sandwiching" in time the readout gradient with a pair of small gradients of equal area and of opposite polarity. While data with non-zero phase shifts between water and fat signals are collected as fractional echoes, no increase in echo spacing is necessary with the modified acquisition strategy, and increased time efficiency is therefore achieved. In order to generate separate water-only and fat-only images in data processing, a set of low-resolution images are first reconstructed from the central symmetric portion (either 128 x 128 or 64 x 64) of the acquired multipoint Dixon data. High-resolution images using all the acquired data, including some partial Fourier-reconstructed images, are then phase demodulated using the phase errors determined from the low-resolution images. The feasibility of the technique is demonstrated using a water and fat phantom as well as in clinical patient imaging.
π SIMILAR VOLUMES
It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization r
## Abstract We present a simple and intuitive means for determining the flip angles (FAs) required for smooth transitions between static pseudo steady states (SPSSs) in fast spin echo (FSE) imaging with variable FA (VFA) echo trains. We demonstrate the effectiveness of single and multiple transitio
A computer simulation has been used to calculate the effects of J coupling on the amplitudes of echoes produced by CPMG sequences. The program computes the evolution of the density matrix for different pulse intervals and can predict the signals obtainable from spin systems of any size and complexit
In this article, the authors illustrate the contributions of incidental magnetization transfer contrast (MTC) to the signal characteristics of patellar cartilage on routine, multiplanar fast spin-echo (FSE) images. Incidental MTC diminishes the signal of patellar cartilage by 30% on routine FSE scan
## Abstract A fast multiβsection MR imaging technique is described. Gradientβ and spinβecho (GRASE) imaging utilizes the speed advantages of gradient refocusing while overcoming the image artifacts arising from static field inhomogeneity and chemical shift. Image contrast is determined by the T2 co