𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Metal capillary column for high temperature gas chromatography

✍ Scribed by Takayama, Y. ;Takeichi, T. ;Kawai, S.


Publisher
John Wiley and Sons
Year
1988
Tongue
English
Weight
239 KB
Volume
11
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Stainless steel capillary columns for hi
✍ Zou, Naizhong ;Yusheng, Tsui ;Jiahe, Sun ;Wanzhen, Lu 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 279 KB

## Abstract A layer of elemental silicon has been deposited on the surface of stainless steel tubing by means of chemical vapor deposition (CVD). Two kinds of capillary column were prepared from the deactivated tubing: cross‐linked, silanol‐terminated polydime‐thylsiloxane wall coated open tubular

High temperature gas chromatography on n
✍ Damasceno, Lucia M. P. ;Cardoso, Jari N. ;Coelho, Ricardo B. 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 338 KB 👁 1 views

## Abstract The use of high‐temperature‐stable, medium polarity glass capillary columns coated with immobilized PS‐090 (a 20 % diphenyl‐substituted, CH~3~O‐terminated polydimethylsiloxane) has made it possible to analyze routinely, and with good separation efficiency, high molecular weight compound

High-speed gas chromatography using pack
✍ Yufeng Shen; Milton L. Lee 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 113 KB 👁 2 views

In this article, fused silica capillaries with an inner diameter of 250 m were packed with 5-and 10-m spherical and irregular silica particles with pore sizes ranging from 60 to 300 A. The columns were investigated for high-speed Ž . separation seconds of light hydrocarbons under gas chromatographic

Aspects of high-temperature capillary ga
✍ Hinshaw, J. V. ;Ettre, L. S. 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 395 KB

Polywax 655 by cold on-column, PT split, and PT splitless injection. A) Cold on-column. B) PT split. C) FTsplitless; 1.0 minute split time. D) pT splitless; 4.0 minute split time. Conditions: column, Al-clad 7 m X 0.25-mm i.d. X 0.1 -pm film, high-temperature methyl silicone; He carrier, 8 psig; spl

Direct injection on capillary columns fo
✍ Chauhan, J. ;Darbre, A. 📂 Article 📅 1981 🏛 John Wiley and Sons 🌐 English ⚖ 417 KB

## Abstract Discrimination may occur when injecting samples onto gas chromatography capillary columns, whereby peak areas for higher boiling point compounds are smaller than they should be compared to lower boiling compounds. This problem is most important in quantitative work on solutes having a w