𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Mechanism for an ion accumulation process in external source fourier transform mass spectrometers

✍ Scribed by S.C. Beu; D.A. Laude Jr.


Publisher
Elsevier Science
Year
1990
Tongue
English
Weight
1004 KB
Volume
97
Category
Article
ISSN
0168-1176

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


An External Source 7 T Fourier Transform
✍ Forest M. White; Jarrod A. Marto; Alan G. Marshall πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 538 KB

An external source 7 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer offers three main novel features. First, a 9-way ion-source cross allows for mounting of up to three ionization sources simultaneously, thereby minimizing 'downtime' for changing ion sources. Second, an electr

Metastable decay of peptide ions on a Fo
✍ Ho, Yen-Peng; Fenselau, Catherine πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 87 KB πŸ‘ 2 views

Metastable decay rates of two peptides, RPPGFSPF and PKPQQFFGLM, were determined from ions produced in an external matrix-assisted laser desorption/ionization source with a Fourier transform mass spectrometer. An isolation and subtraction method that gives difference spectra was employed to monitor

Selected ion accumulation of noncovalent
✍ James E. Bruce; Steven L. Van Orden; Gordon A. Anderson; Steven A. Hofstadler; M πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 1012 KB

An electrospray ionizatiom-Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometer has been used in conjunction with the technique of selected-ion accumulation (SIA) to investigate its utility for the study of the gas phase behavior of noncovalent complexes from solution. SIA is demo

Gas-phase dimerization of dimethylanilin
✍ Maziarz, E. Peter; Wood, Troy D. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 441 KB πŸ‘ 2 views

N,N-Dimethylaniline (DMA) is a common starting material in graft copolymerization and photopolymerization processes when combined with an organic acid. Several anodic oxidation studies of DMA, in an acidic medium, have been performed. Numerous electrochemical studies imply that DMA has a tendency to

Desorption/Ionization of Inorganic Compo
✍ Herbert Struyf; Luc Van Vaeck; RenΓ© Van Grieken πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 896 KB

Application of FT LMMS to inorganic compounds offers the advantage of direct speciation. This means that signals which refer to intact analyte molecules are detected. Cumnt concepts of desorption and ionization in LMMS are mainly based on time-of-llight data and hence on ions formed during the laser