Mechanical testing of the tension band wire fixation in the proximal femur

✍ Scribed by E. E. Engel; J. B. Volpon; A. C. Shimano


Publisher
Springer
Year
1997
Tongue
English
Weight
517 KB
Volume
116
Category
Article
ISSN
1434-3916

No coin nor oath required. For personal study only.

✦ Synopsis


The mechanical stability of proximal femoral osteotomies fixed by the tension band wire technique was studied in flexion-compression and torsion tests. The fixation consisted in crossing the section with two Kirschner wires and with a wire cerclage applied to the tension surface. The study was conducted in three steps. First, cyclinders of wood were cut either transversely or at 30 degrees of inclination in relation to the long axis of the specimen, and fixed with two Kirschner wires and a wire cerclage. We concluded that the inclination of the plane of section significantly increased the stability of fixation. No significant difference was observed when oblique sections were made in the reverse orientation. Second, 30 degrees subtrochanteric varus osteotomies were performed in dog femurs, so that the section plane was transverse in one group and oblique in another, after closing the osteotomy. In both groups the fixation was achieved by two Kirschner wires that crossed the osteotomy and a wire cerclage placed on the lateral cortex (tension surface). We concluded that inclination of the osteotomy plane increased the stability of osteosynthesis in bone specimens, as already seen with the wood pieces. Third, the stability of tension band wire fixation was compared with that provided by the AO/ASIF paediatric angled plate. Varus osteotomies (30 degrees) were created at the subtrochanteric level of paired dog femurs. On one side, the femur was fixed with Kirschner wires and a wire cerclage as described previously. For the other femur, the osteotomy was fixed with the angled plate. We found that both types of fixation presented the same stability in flexion-compression tests. However, under torsion the tension band wire fixation was 30%-50% less stable than the plate fixation.


📜 SIMILAR VOLUMES


Bioceramic inlays do not improve mechani
✍ Pauli Keränen; Jyri Koort; Ari Itälä; Heimo Ylänen; Michel Dalstra; Mikko Hupa; 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 382 KB

## Abstract The aim of the present study was to determine, if bioactive glass (BG) surface inlays improve osseointegration of titanium implants in the proximal femur of adult sheep. In simulation of uncemented primary stems (nine animals), only the proximal part of the implants was grit‐blasted and

Mechanical properties in tension of mech
✍ T.R. Malow; C.C. Koch 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 933 KB

AbstractÐThe mechanical properties of warm compacted nanocrystalline (nc) iron powder compacts of near theoretical density in the grain size range between 8 and 33 nm were investigated. The elastic and plastic behavior were characterized by miniaturized disk bend tests and hardness measurements. Lig