𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests

✍ Scribed by K. Bruyère Garnier; R. Dumas; C. Rumelhart; M.E. Arlot


Publisher
Elsevier Science
Year
1999
Tongue
English
Weight
708 KB
Volume
21
Category
Article
ISSN
1350-4533

No coin nor oath required. For personal study only.

✦ Synopsis


In order to investigate and compare the mechanical behaviour of human cancellous bone during different shear loading modes, two tests were performed to characterise human femoral cancellous bone in shear: a torsion test until failure and a shear test using a sharpened stainless steel tube. Paired cylindrical samples were core drilled from 12 human femoral heads, symmetrically with respect to the coronal plane and along the primary trabecular direction. The distal part of the sample was assigned to a torsion test and the shear test was performed on the proximal part along two perpendicular anatomical directions. Apparent densities and tissue densities were measured on both torsion and shear specimens. The mean torsion properties were shear modulus G, 289 (183) MPa, ultimate stress tau(torsion), 6.1 (2.7) MPa, ultimate strain gamma(ultimate), 4.6 (1.3)%, yield stress tau(yield), 4.3 (1.9) MPa and yield strain gamma(yield), 1.8 (0.3)%. Strong correlation was obtained between G and tau(torsion) (r'=0.853, p<0.001). These torsion properties were correlated with apparent density of torsion specimens showing, respectively: r'=0.713, p=0.005 and r'=0.671, p=0. 008. Properties from the shear test were invariable with regard to the two tested directions then isotropic ultimate shear stress and isotropic elementary shear stress, which represent the mean values of the two tested directions were, respectively, tau(shear), 10.0 (4. 5) MPa and tau(elem), 18.8 (6.1) MPa. Both shear stresses were correlated with apparent density of shear specimens: tau(shear), r'=0.564, p=0.045 and tau(elem), r'=0.636, p=0.024. Apparent densities for shear specimens were superior than for torsion specimens (p=0.06) and the comparison was the opposite for tissue densities (p=0.028), showing strong density gradients of cancellous bone in the femoral head. These torsion and shear tests which permit the evaluation of cancellous bone behavior under two different types of shear loading, may be performed on different human sites and the measured shear properties may be compared to structural properties of cancellous bone.


📜 SIMILAR VOLUMES


Functional dependence of cancellous bone
✍ Ara Nazarian; Diego Meier; Ralph Müller; Brian D. Snyder 📂 Article 📅 2009 🏛 Elsevier Science 🌐 English ⚖ 281 KB

## Abstract When compressed axially, cancellous bone often fails at an oblique angle along well‐defined bands, highlighting the importance of cancellous bone shear properties. Torsion testing to determine shear properties of cancellous bone has often been conducted under conditions appropriate only

Cartilage degeneration in post-collapse
✍ Robert A. Magnussen; Farshid Guilak; Thomas P. Vail 📂 Article 📅 2005 🏛 Elsevier Science 🌐 English ⚖ 748 KB

Osteonecrosis, or avascular necrosis, is a painful and debilitating condition characterized by progressive joint degeneration subsequent to collapse of necrotic regions of trabecular bone. A clear understanding of the mechanism of cartilage degeneration in osteonecrosis is critical to the developmen

Tensile and torsional shear strength of
✍ L. Pröbster; CH Voigt; G. Fuhrmann; U. M. Gross 📂 Article 📅 1994 🏛 Springer 🌐 English ⚖ 760 KB

The effect of three different titanium plasma flame spray coatings on the tensile strength and the effect of macrostructures on the torsional shear strength of the bone implant interface was studied. Titanium cylinders, of 8 mm length and 4 mm diameter, were implanted into distal rabbit femurs. For

Nondestructive measurements of implant-b
✍ Berzins, A. ;Shah, B. ;Weinans, H. ;Sumner, D. R. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 122 KB

Push-out and pull-out tests are used for destructive evaluation of implant-bone interface strength. Because nondestructive mechanical tests would allow maintenance of an intact interface for subsequent morphological study, we developed such a test to determine the shear modulus of the interface by m