✦ Synopsis


Abstract

Impaction allografting is an attractive procedure for the treatment of failed total hip replacements. The graft–cement–host bone interface after impaction allografting has not been characterized, although it is a potential site of subsidence for this type of revision total hip reconstruction. In six human cadaveric femurs, the cancellous bone was removed proximally and local diaphyseal lytic defects were simulated. After the impaction grafting procedure, the specimens were sectioned in 6 mm transverse sections and pushout tests were performed. From the adjacent sections the percentage cement contact of the PMMA cement with the endosteal bone surface was determined. The host bone interface mechanical properties varied significantly along the femur largely due to different interface morphologies. The apparent host bone interface shear strength was highest around the lesser trochanter and lowest around the tip of the stem. A significant positive correlation was found between the percentage cement contact and the apparent host bone interface shear strength (r^2^ = 0.52). The sections failed in 69% of the cases through a pure host bone interface failure without cement or allograft failure, 19% failed with local cement failure, and 12% with a local allograft failure. The apparent host bone interface strength was on average 89% lower than values reported for primary total hip replacements and were similar to cemented revisions proximally and lower distally. This study showed that cement penetration to the endosteal surface enhanced the host bone–graft interface. © 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.


📜 SIMILAR VOLUMES


Impaction allografting—The effect of imp
✍ Carolyne Albert; Bassam Masri; Clive Duncan; Thomas Oxland; Göran Fernlund 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 291 KB

## Abstract Revision total hip replacement with impaction allografting has an attractive potential for restoring bone stock, however, fractures and implant migration remain problematic. Postoperative graft deformation is believed to contribute to migration. Under compressive loading, the fluid in t

Mechanical characteristics of the stem-c
✍ Kenneth A. Mann; Dr. Donald L. Bartel; Timothy M. Wright; Anthony R. Ingraffea 📂 Article 📅 1991 🏛 Elsevier Science 🌐 English ⚖ 910 KB

## Abstract The mechanical characteristics of the interface between a metallic stem and the surrounding poly(methyl methacrylate) bone cement were determined from experimental tests and finite element analyses. Push‐through‐stem tests of straight and tapered titanium alloy stems, surrounded by ceme

Biological and mechanical characteristic
✍ Gina M. Gualtieri; Sorin Siegler; Eric L. Hume; Surya R. Kalidindi 📂 Article 📅 2000 🏛 Elsevier Science 🌐 English ⚖ 620 KB

## Abstract We recently evaluated the peak pullout loads for anchors made from our new copolymeric swellingtype material compared with anchors made of a nonswelling material. __In vitro__ and __in vivo__ peak pullout loads of these anchors were evaluated after different intervals of implantation in

Biological reconstruction after resectio
✍ Marco Innocenti; Yasser Y. Abed; Giovanni Beltrami; Luca Delcroix; Marco Manfrin 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract Reconstruction after excision of bone tumor of the proximal tibia is a challenging issue for the reconstructive surgeon. The combined use of a free fibular flap and allograft can provide a reliable reconstructive option in this location. This article describes the authors' long‐term fol