Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4V implants in tibia bone

✍ Scribed by Chang, C. K. ;Wu, J. S. ;Mao, D. L. ;Ding, C. X.


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
652 KB
Volume
56
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


This paper evaluates the behavior of hydroxyapatite (HAP) coated and noncoated Ti6Al4V implants in dog tibia after 3 and 5 months implantation. HPA-coated implants were obtained by plasma spraying. XRD, SEM, and EPMA were employed to estimate the coating characteristics and their behavior in vivo. Investigation of material characteristics showed that the as-received coatings consisted mainly of amorphism and HAP phase. Other phases such as TCP and CaO were identified due to thermal changes of HAP particles in plasma flame. SEM micrographs showed a typical microstructure of plasma-sprayed coating. The asreceived coating was formed by well-melted pancake-like splats that lead to a dense coating with a rough surface. Lamellar structure, micropores, and microcracks, observed inside the coating, are characteristic of plasma spraying. Push-out tests revealed that HAP coating had a significant promotion of interfacial shear strength. The shear strength between bone and HAP-coated implants was much higher than that between bone and noncoated implants due to the different bone-implant interfaces formed after implantation. SEM observation revealed a direct attachment between HAP coating and newly formed bone. However, noncoated implants were separated from newly formed bone by fibrous tissues. Ti ions were found to be released into the surrounding environment after long time immersion in body fluid, and thus caused low shear strength. Prolongation of implantation time had different effects on shear strength. It improved the shear strength between HAP-coated implant and newly formed bone. However, it had little effect on that between noncoated implant and surrounding tissues.


πŸ“œ SIMILAR VOLUMES


Osseointegration of hydroxyapatite-coate
✍ Oosterbos, C. J. M. ;Vogely, H. Ch. ;Nijhof, M. W. ;Fleer, A. ;Verbout, A. J. ;T πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 177 KB πŸ‘ 1 views

## Abstract A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA‐coated or noncoated Ti cylinders

Characterization and in vivo evaluation
✍ A. Balamurugan; A. Rebelo; S. Kannan; J.M.F. Ferreira; J. Michel; G. Balossier; πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 410 KB πŸ‘ 1 views

## Abstract Hydroxyapatite (HAP) based coatings on titanium alloy Ti6Al4V were attempted by sol–gel process. Precursor sol was dip‐coated onto the substrates and the formation of HAP as the main phase was ensured after the sintering of coatings at 900Β°C, as confirmed by the characterization studies

Effects of hydroxyapatite coating on Ti-
✍ H. Ch. Vogely; C. J. M. Oosterbos; E. W. A. Puts; M. W. Nijhof; P. G. J. Nikkels πŸ“‚ Article πŸ“… 2000 πŸ› Elsevier Science 🌐 English βš– 999 KB

## Abstract To investigate the effect of implant type after direct contamination, a hydroxyapatite‐coated or noncoated Ti‐6Al‐4V implant was inserted into both tibiae of 32 New Zealand White rabbits. Prior to implantation, the left tibia was contaminated with increasing concentrations of __Staphylo

Wear-accelerated corrosion of Ti-6Al-4V
✍ Buchanan, R. A. ;Rigney, E. D. ;Williams, J. M. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 725 KB

Wear-accelerated corrosion rates at constant anodic potentials were evaluated for unimplanted and nitrogen-ion-implanted surgical Ti-6A1-4V while wearing against ultrahigh-molecular-weight polyethylene at stress levels up to 6.90 MPa (1000 psi). The ion implantation processing was found to reduce th

Stress enhancement and fatigue susceptib
✍ Messersmith, Phillip B. ;Cooke, Francis W. πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 704 KB

An elastic stress analysis of porous-coated implant surfaces was performed using the finite element method. Three-hundredpm-diameter metal beads sinter bonded onto an implant surface were modeled with sinter neck radii of 5, 10, 20, and 50 pm. Smooth-surface, single-bead, single-layer, and double-la