𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measuring the relative interface thickness of multilayer polyolefin films with atomic force microscopy

✍ Scribed by Rajesh P. Paradkar; Jing Li; Georg Bar; Hoang Pham; Clive Bosnyak; Jeffrey Weinhold


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
838 KB
Volume
106
Category
Article
ISSN
0021-8995

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In any polymer blend system, the nature and thickness of the polymer interface can have a significant influence on the overall performance of the blend. Consequently, it is important to understand the nature of the interactions between the various blend components to effectively design blend combinations with desired end‐use properties. However, because of the inherent level of difficulty, the quantitative measurement of the interface thickness in immiscible polymer blends has not been accomplished or reported in the literature. Atomic force microscopy in the tapping mode has been employed to establish a systematic methodology to measure the relative interface thickness of seven types of coextruded multilayer polyolefin films. Criteria have been developed to define profiles of the interface and estimate the interface thickness from these profiles. The effects of tip indentation on the measured value of the interface thickness are also considered. The atomic force microscopy method presented here allows for a direct quantitative estimate of the interface thickness in multilayer polyolefin films, which in turn provides a significantly better understanding of physical properties such as tear in coextruded blown films and the toughness/stiffness balance in injection‐molded impact copolymers. Β© 2007 Wiley Periodicals, Inc. J Appl Polym Sci 2007


πŸ“œ SIMILAR VOLUMES


In-situ thickness measurement of porous
✍ Dongxian Zhang; Haijun Zhang; Yulin He πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 175 KB

This article presents a novel method to measure the in situ thickness of porous alumina (PA) films. The PA films were prepared in oxalic acid at 30, 40, and 60 V direct current. Based on the atomic force microscope measurements, PA film porosities and refractive indexes measurements were acquired. W

P-selectin/ligand unbinding force measur
✍ Theodora Tsapikouni; Yannis F. Missirlis πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 764 KB

## Abstract Leukocytes, as an indispensable arm of the immune system, need to be recruited from the flowing blood and transferred to the sites of infection. Their extravasation is feasible due to their ability to tether and roll over the activated endothelium, which is much dependent on the associa