𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measuring optical properties of an eye lens using magnetic resonance imaging

✍ Scribed by C.E Jones; J.M Pope


Publisher
Elsevier Science
Year
2004
Tongue
English
Weight
374 KB
Volume
22
Category
Article
ISSN
0730-725X

No coin nor oath required. For personal study only.

✦ Synopsis


We compare the focal lengths of porcine lenses measured optically and by using a novel MRI technique. The geometric properties of the lenses were also measured and compared. The MRI technique exploits the dependence of both the lens refractive index and relaxation rates on the local protein concentration. By measuring the refractive index and corresponding values of R2 (=1/T2) for samples of lens homogenates with different protein concentrations, the dependence of refractive index on R2 was determined empirically. R2 maps, constructed from monoexponential fits to multiecho images of a slice through the lens containing the optical axis, were converted to refractive index maps using this relationship. A simulated ray trace through the refractive index map provided an estimate of lens focal length that was compared to a direct optical measurement of focal length using a laser ray-tracing method. It was found that the mean focal lengths estimated from the two techniques agreed within experimental uncertainty. The refractive index profile along the optical axis was found to be well described by a simple function of the form n=n0 + n1 x ra where r is the (normalized) lens radius.


πŸ“œ SIMILAR VOLUMES


Magnetic Resonance Imaging Measurement o
✍ Zhiyue J. Wang; Shuchun Li; John C. Haselgrove πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 140 KB

A magnetic resonance imaging method is described for measuring the magnetic susceptibility difference between two homogeneous macroscopic compartments in contact with each other. A boundary condition is derived for the interface of the two compartments. This boundary condition predicts that across t

Magnetic resonance imaging of the uterin
✍ C. J. Baudouin; W. P. Soutter; D. J. Gilderdale; G. A. Coutts πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 402 KB πŸ‘ 1 views

## Abstract Cylindrical receiver coils designed for intravaginal use were utilized to image the uterine cervix. Good quality images of the cervix, vaginal wall, and parametrium were obtained and patient tolerance of the procedure was good. Β© 1992 Academic Press, Inc.

Comparison of Scalar Measures Used in Ma
✍ Mark M. Bahn πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 356 KB

The tensors derived from diffusion tensor imaging describe complex diffusion in tissues. However, it is difficult to compare tensors directly or to produce images that contain all of the information of the tensor. Therefore, it is convenient to produce scalar measures that extract desired aspects of