Several commercial UF-membranes are characterized by water contact angles. Two different methods of contact angle measurements, the sessile drop and the captive bubble methods, are compared. Differences in results between the two methods occur for the DDS CR 61 membrane; otherwise the methods give r
โฆ LIBER โฆ
Measuring hydrophilicity of RO membranes by contact angles via sessile drop and captive bubble method: A comparative study
โ Scribed by Youngbin Baek; Junil Kang; Patrick Theato; Jeyong Yoon
- Book ID
- 118046525
- Publisher
- Elsevier Science
- Year
- 2012
- Tongue
- English
- Weight
- 602 KB
- Volume
- 303
- Category
- Article
- ISSN
- 0011-9164