𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurements of the nonlinearity parameter BA of contrast agents

✍ Scribed by Junru Wu; Jie Tong


Publisher
Elsevier Science
Year
1998
Tongue
English
Weight
546 KB
Volume
24
Category
Article
ISSN
0301-5629

No coin nor oath required. For personal study only.

✦ Synopsis


The nonlinearity parameter B/As of two contrast agents (Albunex and Levovist) in a saline solution (Isoton II) were measured. The results show that B/As of both contrast agents were increasing functions of bubble number densities. In general, they are much higher than that of most soft tissues. For Albunex (concentration = 1 microL Albunex: 1 mL Isoton) a B/A of 2000; and for Levovist (concentration = 6.0 mg Levovist powder: 1 mL Isoton), a B/A of 600 was obtained.


πŸ“œ SIMILAR VOLUMES


Quantitative measurements of second harm
✍ Pi Hsien Chang; K.Kirk Shung; Harold B. Levene πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 983 KB

Quantitative measurements of second harmonic and first harmonic Doppler were carried out using two ultrasound contrast agents, Albunexc and FS069. The RMS amplitudes of the Doppler shift spectra were measured as a function of the concentration of the agents, frequency and transmitted acoustic pressu

Reliability of pharmacokinetic parameter
✍ Karolien Jaspers; Hugo J.W.L. Aerts; Tim Leiner; Marlies Oostendorp; Natal A.W. πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 720 KB

## Abstract Current clinical applications of dynamic contrast‐enhanced MRI (DCE‐MRI) are based on the extravasation of relatively small contrast agents (SCAs). SCAs are considered disadvantageous, as they require high image sampling rates. Medium‐sized contrast agents (MCAs) leak more slowly into t

Improving the reliability of obtaining t
✍ C. C. Quarles; B. D. Ward; K. M. Schmainda πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 638 KB

## Abstract A new approach to improve the reliability of dynamic susceptibility contrast MRI for the evaluation of brain tumor hemodynamics in the presence of contrast agent extravasation is described. This model‐based technique simultaneously estimates the voxel‐wise tumor residue function and the

Measurement of electro-optical parameter
✍ R. Karapinar; M. O’Neill; M. Hird πŸ“‚ Article πŸ“… 2009 πŸ› Elsevier Science 🌐 English βš– 258 KB

We have fabricated a ferroelectric liquid crystal (FLC) film by using a novel ferroelectric mixture. The various ferroelectric parameters such as response time, spontaneous polarization and contrast ratio of the FLC film have been measured. Experimental results show that the FLC film exhibits high c