Measurement of the exposure rate due to low energy x-rays emitted from video display terminals
โ Scribed by L.L. Campos
- Publisher
- Elsevier Science
- Year
- 1988
- Weight
- 215 KB
- Volume
- 39
- Category
- Article
- ISSN
- 0883-2889
No coin nor oath required. For personal study only.
โฆ Synopsis
Thermoluminescent
dosimeters of CaSO,: Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately SO". The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h-' (0.129pC kg-' h-') which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection.