𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of serum unconjugated estriol and estradiol by high-performance liquid chromatography

✍ Scribed by Zenjiro Kondo; Tsunehisa Makino; Rihachi Lizuka


Publisher
John Wiley and Sons
Year
1990
Tongue
English
Weight
327 KB
Volume
4
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Measurement of Estriol (E~3~) and estradiol (E~2~) within 22 min by high‐performance liquid chromatography (HPLC) was achieved in this study, and the values were compared with those of a radioimmunoassay (RIA). A totally computerized HPLC method was developed for measuring unconjugated E~3~(u‐E~3~) and E~2~ (u‐E~2~) in the sera of pregnant women. The serum samples were injected directly into the apparatus and transferred to a pre‐treatment column where the estrogens were absorbed while hydrophilic components such as proteins and carbohydrates were excluded. The estrogens were then passed through another separation column containing a new type of polymer gel. The mobile phase consisted of an acetonitrile‐water mixture, and separation was achieved by means of a reversed‐phase procedure. The eluate was monitored for fluorescence. All procedures were monitored and controlled with a built‐in microcomputer. Serum samples from 97 normal pregnant women at 20–41 wk gestation were simultaneously assayed by HPLC and RIA. The correlations obtained by HPLC and RIA were as follows: u‐E~3~ y = 0.905x–0.385, with a coefficient of correlation of r = 0.912; for u‐E~2~, y = 0.964x + 5.024, with a coefficient of correlation of r = 0.841 (y, RIA value; x, HPLC value). The quick measurement of u‐E~3~ and u‐E~2~ by HPLC can be a useful method for evaluating fetoplacental function.


πŸ“œ SIMILAR VOLUMES


Simultaneous measurement of serum retino
✍ L. A. Kaplan; J. A. Miller; E. A. Stein πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 429 KB

An isocratic, high-performance liquid chromatography method is presented for the simultaneous analysis of retinol, tocopherols, carotenes, and other carotenoids. The method employs detection at two wavelengths (292 and 450 nm) and three internal standards, which are: retinyl acetate, alpha-tocophery

Measurement of albuterol in guinea pig s
✍ James R. Loss II; Raymond F. Orzechowski; Rick S. Hock πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 62 KB πŸ‘ 2 views

A sensitive, simple and reproducible high performance liquid chromatographic method for detecting and quantifying albuterol in guinea pig serum is described. A structurally related compound, bamethan, was used as an internal standard. The method employs ion-pair extraction with di(2-ethylhexyl)phosp

Determination of phenylpropanolamine in
✍ R. Dowse; J. M. Haigh; I. Kanfer πŸ“‚ Article πŸ“… 1983 πŸ› John Wiley and Sons 🌐 English βš– 355 KB

A high-performance liquid chromatographic analysis of phenylpropanolamine in human serum and urine without prior derivatization is presented. Using direct UV detection the method is sufficiently sensitive to detect 25 ng of drug/ml of serum or urine; the coefficients of variation at 25 ng/ml and 500