𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of Orientation Distributions Using Chemical Shift Amplification

✍ Scribed by Charles Crockford; Helen Geen; Jeremy J. Titman


Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
771 KB
Volume
22
Category
Article
ISSN
0926-2040

No coin nor oath required. For personal study only.

✦ Synopsis


A new three-dimensional magic angle spinning (MAS) experiment is proposed, based on a combination of the two-dimensional rotor-synchronized MAS experiment of Spiess and co-workers and a new chemical shift anisotropy amplification method. The new experiment is demonstrated on a macroscopically ordered sample of ultra-high molecular weight poly(ethylene).


πŸ“œ SIMILAR VOLUMES


Measurement of fiber orientation distrib
✍ Adam W. Anderson πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 346 KB

## Abstract High angular resolution measurements of diffusion are used to estimate the angular distribution and diffusion anisotropy of fibers in a voxel. A simple, axially symmetric model of diffusion in white matter fibers is used to relate diffusion measurements to fiber properties. The new tech

Analysis of N-terminal capping using car
✍ Soon-Ho Park; William Shalongo; Earle Stellwagen πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 118 KB

The model peptide XAAAAE-AAARAAAARamide is used to examine the contributions of an N-terminal capping interaction to the conformation and stability of a helical ensemble. The reference peptide has an alanine residue at position X while the capping peptide has a serine residue at this position. The h

Use of an internal reference in 13C chem
✍ D. G. de Kowalewski; C. de Los Santos; E. Marceca πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 300 KB

## Abstract The use of the nominal value of the chemical shift of the solvent to calibrate the spectrometer in ^13^C NMR spectroscopy was found to introduce errors due to the effect which the solute has on the solvent. In addition, hexamethyldisiloxane (HM) is proposed as an internal standard; owin

Measurement of temperature dependent cha
✍ Brian A. Taylor; Andrew M. Elliott; Ken-Pin Hwang; Anil Shetty; John D. Hazle; R πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 929 KB

## Abstract ## Purpose: To provide quantitative temperature monitoring for thermal therapies in bone marrow by measuring temperature‐dependent signal changes in the bone marrow of ex vivo canine femurs heated with a 980‐nm laser at 1.5T and 3.0T. ## Materials and Methods: Using a multi‐gradient