𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Measurement of glycine in human prefrontal brain by point-resolved spectroscopy at 7.0 tesla in vivo

✍ Scribed by Changho Choi; Deborah Douglas; Halima Hawesa; Ashish Jindal; Charles Storey; Ivan Dimitrov


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
516 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Measurement of glycine in human frontal brain by an optimized point‐resolved spectroscopy sequence at 7 T is reported. Echo time dependencies of the overlapping coupled resonances of myo‐inositol, free choline, and threonine were investigated with density matrix simulations, incorporating the slice‐selective radiofrequency and gradient pulses. The numerical simulations indicated that the selectivity of the 3.55‐ppm glycine singlet is maximized at (TE~1~, TE~2~) = (101, 51) ms. Phantom experiments indicated that the myo‐inositol peak amplitude between 3.5 and 3.6 ppm is reduced by a factor of 30 following the optimized point‐resolved spectroscopy, as predicted by the simulation. From LCModel analyses, the glycine concentration in the medial prefrontal cortex in healthy adults was estimated, with a mean Cramér‐Rao lower bound of 7 ± 1% (mean ± standard deviation; n = 7), to be 0.8 ± 0.1 mM, with reference to total creatine at 8 mM. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Measurement of glycine in human brain by
✍ Changho Choi; Paramjit P. Bhardwaj; Peter Seres; Sanjay Kalra; Philip G. Tibbo; 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 573 KB

## Abstract A new ^1^H‐MRS filtering strategy for selective measurement of glycine (Gly) in human brain in vivo at 3.0T is proposed. Investigation of multiple refocusing following a 90° excitation pulse indicated that triple refocusing is most effective for suppression of the strongly coupled reson

In vivo detection of serine in the human
✍ Changho Choi; Ivan Dimitrov; Deborah Douglas; Chenguang Zhao; Halima Hawesa; Sub 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 349 KB 👁 1 views

## Abstract A single‐voxel proton magnetic resonance spectroscopy (^1^H‐MRS) filtering strategy for in vivo detection of serine (Ser) in human brain at 7T is proposed. Spectral difference of coupled resonances arising from different subecho times of triple refocusing at a constant total echo time (

Detection of glutamate in the human brai
✍ Dirk Mayer; Daniel M. Spielman 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 209 KB 👁 1 views

## Abstract A CT‐PRESS sequence was implemented on a 3‐T MR scanner and optimized for the detection of the C4 resonance of glutamate. By simulating the sequence using the full density matrix it was found that 121 chemical shift encoding steps in __t__~1~ with an increment Δ__t__~1~ = 1.6 ms were su

Measurement of variation in the human ce
✍ Masafumi Harada; Hitoshi Kubo; Ayumi Nose; Hiromu Nishitani; Tsuyoshi Matsuda 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 296 KB 👁 2 views

## Abstract The objectives of this study were to examine the reproducibility of the MEGA‐editing J‐difference technique and to determine the normal variation in the γ‐aminobutyric acid (GABA) level depending on the cerebral region and its fluctuation according to the menstrual cycle as baseline dat