✦ Synopsis


Nitric oxide (NO) can be measured directly in expired air in adults. The purpose of our study was to measure NO levels in children and to compare these values with adults. Exhaled NO was measured in 39 normal prepubertal children (23 girls), aged 9-11 years (mean, 9.9 years). Exhaled NO was measured by the chemiluminescence method that is sensitive in a range of 2 to 4,000 ppb of NO on an adapted analyzer (Dasibi Environmental). Wearing a nose clip, 5 measurements were recorded in each child with exhalation 1) directly into the NO analyzer (flow rate 240 mUmin) with measurements of NO, carbon dioxide, and mouth pressure; and 2) using a T-piece to allow measurements at a different flow rate. For all measurements, background NO levels were less than 10 ppb. The mean direct level was 49.6 ppb, SD 37.8 (range,2 ppb) compared with T-piece levels of 29.2 ppb, SD 27.1 (range, 5.1-141.2 ppb). There was no significant difference between boys and girls for direct or T-piece recordings. Mean direct NO in boys was 43.1 ppb, SD 40.5 and in girls 55.2 ppb, SD 35.4; mean T-piece in boys was 25.6 ppb, SD 29.2, and in girls 33.8 ppb, SD 25.1. Mean NO levels in prepubertal children are lower than in adults and show no difference between males and females.


πŸ“œ SIMILAR VOLUMES


Exhaled nitric oxide measurements in nor
✍ C. A. Byrnes; S. Dinarevic; E. A. Shinebourne; P. J. Barnes; A. Bush πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 97 KB πŸ‘ 1 views

The aim of this study was to determine whether we could measure exhaled nitric oxide (NO) levels in children, and whether the same pattern of exhaled NO concentrations was observed in asthmatic and normal children as had been seen in adults. Using a chemiluminescence NO analyzer, we measured NO in e

Effect of atmospheric nitric oxide (NO)
✍ E. Baraldi; N. M. Azzolin; C. Dario; S. Carra; R. Ongaro; P. Biban; F. Zacchello πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 44 KB πŸ‘ 2 views

The measurement of exhaled nitric oxide concentrations [NO] may provide a simple, noninvasive means for measuring airway inflammation. However, several measurement conditions may influence exhaled NO levels, and ambient NO may be one of these. We measured exhaled NO levels in 47 stable asthmatic chi

Measurement of faecal immunoglobulin a l
✍ Carine Dion; Paul Montagne; Marie Christine Bene; Gilbert Faure πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 92 KB

## Abstract A nephelometric immunoassay was developed to quantify immunoglobulin A (IgA) in children's stools. This method enables IgA in faecal protein extracts to be measured over a large range of concentrations (1.61–51.50 mg/L) with good accuracy (linear recovery in dilution‐overloading assay)

A two-photon absorption cross section me
✍ J. Burris; T.J. McGee; T.J. McIlrath πŸ“‚ Article πŸ“… 1983 πŸ› Elsevier Science 🌐 English βš– 432 KB

NC report here the mc~wrsment of 3 Tao-photon absorption crocs section for the R22 +Srz (J" = 9.5) [A '\"(a~'= 0) -S 'll(u'= 0)) tnn\ition in the gamma band s>stcm of nitric oxide by measuring the third-order susceptibilit>~ usins ZI four-~.ne mi\ing tcrlmiqw. A vsluc of oc2) = (1.0 f 0.6) X 1O-3s n