Abstract

The material properties of cortical bone from the diaphyses of long bones (e.g., the femur and tibia) vary by direction, such that bone is stiffer and stronger along its long axis. This configuration improves the abilities of these structures to resist axial compressive loads coupled with bending. As in long bones, cortical bone from the cranial vault is subject to mechanical loads from various orofacial functions and the contraction of attached muscles. However, experimental studies suggest that the resulting bone strains are at least an order of magnitude smaller than those found in the midshafts of the femur or tibia. The characteristics of the three‐dimensional elastic properties of cortical bone are largely unexplored in regions of low bone strain, including the cranial vault, in which little is known regarding cortical structure and function. In the present study we examined variations in the cortical microstructure and material properties of the bone of the human cranial vault, including the parietal, frontal, temporal, and occipital bones. A facial bone, the zygoma, was also included to contrast the properties of the cranial vault with another craniofacial intramembranous bone that experiences larger strains. Cortical specimens from the outer cortical plate of the cranial vault were removed from 15 frozen human crania. We measured cortical thicknesses and densities, and determined the primary direction of stiffness within the bone specimens prior to ultrasonic testing to determine their elastic properties. There were statistically significant differences in elastic properties between bones and, in some cases, sites within bones, which for most variables were clustered by bone or region. In striking contrast to this pattern, elastic moduli in the direction of primary stiffness were larger in cortical regions underlying muscle attachments than in regions without muscle attachments. Few sites in the cranial vault or zygoma showed a consistent orientation of the material axes among individuals, although specimens from many regions had directional differences similar to those in cortical bone from the mandible, femur, or tibia. Anat Rec Part A 274A:785–797, 2003. Β© 2003 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


Subaponeurotic implantation cyst complic
✍ Lambert Rogers πŸ“‚ Article πŸ“… 1943 πŸ› John Wiley and Sons 🌐 English βš– 200 KB

INDRIVEN epithelial cells must b e of daily which was tense and slightly tender, was deep to the occurrence, yet implantation cysts are quite scalp, which moved freely over it. Electro-encephdomcommon. T h e y are usually Seen on the fingers graphy gave negative results on two different occasions. o

Comparison of the dielectric properties
✍ Dr. C. Gabriel; R. H. Bentall; E. H. Grant πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 255 KB πŸ‘ 1 views

Measurements have been made of the permittivity and conductivity of normal and wounded human slan material over the frequency range 10 MHz-I0 GHz. The permittivity of the wounded tissue was found to be about 12% higher than that of the normal tissue. A similar percentage increase was observed for th