๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Magnetic resonance imaging of mouse spinal cord

โœ Scribed by Mehmet Bilgen; Baraa Al-Hafez; Nancy E.J. Berman; Barry W. Festoff


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
199 KB
Volume
54
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

The feasibility of performing highโ€resolution in vivo MRI on mouse spinal cord (SC) at 9.4 T magnetic field strength is demonstrated. The MR properties of the cord tissue were measured and the characteristics of water diffusion in the SC were quantified. The data indicate that the differences in the proton density (PD) and transverse relaxation time between gray matter (GM) and white matter (WM) dominate the contrast seen on the mouse SC images at 9.4 T. However, on heavily T~2~โ€weighted images these differences result in a reversal of contrast. The diffusion of water in the cord is anisotropic, but the WM exhibits greater anisotropy and principal diffusivity than the GM. The quantitative data presented here should establish a standard for comparing similar measurements obtained from the SCs of genetically engineered mouse or mouse models of SC injury (SCI). Magn Reson Med, 2005. ยฉ 2005 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Human cervical spinal cord funiculi: Inv
โœ Mihaela Onu; Patricia Gervai; Julien Cohen-Adad; Jane Lawrence; Jennifer Kornels ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 334 KB

## Abstract ## Purpose: To use spinal cord diffusion tensor imaging (DTI) for investigating human cervical funiculi, acquire axial diffusion magnetic resonance imaging (MRI) data with an inโ€plane resolution sufficient to delineate subquadrants within the spinal cord, obtain corresponding DTI metri

Functional magnetic resonance imaging in
โœ Jaivijay Ramu; Kurt H. Bockhorst; Kishore V. Mogatadakala; Ponnada A. Narayana ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 484 KB

## Abstract Functional MRI (fMRI) on spinal cordโ€injured rodents at 4 and 8 weeks post injury (PI) is described. The paradigm for fMRI, based on electrical stimulation of rat paws, was automated using an inโ€house designed microprocessorโ€based controller that was interfaced to a stimulator. The MR i

Functional magnetic resonance imaging of
โœ Krisztina L. Malisza; Cheryl Jones; Marco L.H. Gruwel; Derek Foreman; Paul Ferny ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 393 KB

## Abstract ## Purpose To determine if differences exist between control and diabetic rats in functional magnetic resonance imaging (fMRI) activity of the spinal cord and if fMRI can provide a means of early detection of diabetic neuropathy. ## Materials and Methods fMRI of the spinal cord, usin

31P magnetic resonance spectroscopy of t
โœ Robert Vink; Susan M. Knoblach; Alan I. Faden ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 327 KB

31P magnetic resonance spectroscopy (MRS) was applied in vivo to study metabolic changes in spinal cord after experimental traumatic injury. Severe trauma, resulting in spastic paraplegia, caused an early and sustained loss of high energy phosphates with profound intracellular acidosis. Early metabo