𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic resonance imaging of articular cartilage of the knee: Comparison between fat-suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy

✍ Scribed by Hiroshi Yoshioka; Kathryn Stevens; Brian A. Hargreaves; Daniel Steines; Mark Genovese; Michael F. Dillingham; Carl S. Winalski; Philipp Lang


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
733 KB
Volume
20
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To compare signal‐to‐noise ratios (S/N) and contrast‐to‐noise ratios (C/N) in various MR sequences, including fat‐suppressed three‐dimensional spoiled gradient‐echo (SPGR) imaging, fat‐suppressed fast spin echo (FSE) imaging, and fat‐suppressed three‐dimensional driven equilibrium Fourier transform (DEFT) imaging, and to determine the diagnostic accuracy of these imaging sequences for detecting cartilage lesions in osteoarthritic knees, as compared with arthroscopy.

Materials and Methods

Two sagittal fat‐suppressed FSE images (repetition time [TR] / echo time [TE], 4000/13 [FSE short TE] and 4000/39 [FSE long TE]), sagittal fat‐suppressed three‐dimensional SPGR images (60/5, 40° flip angle), and sagittal fat‐suppressed echo‐planar three‐dimensional DEFT images (400/21.2) were acquired in 35 knees from 28 patients with osteoarthritis of the knee. The S/N efficiencies (S/Neffs) of cartilage, synovial fluid, muscle, meniscus, bone marrow, and fat tissue, and the C/N efficiencies (C/Neffs) of these structures were calculated. Kappa values, exact agreement, sensitivity, specificity, positive predictive value, and negative predictive value were determined by comparison of MR grading with arthroscopic results.

Results

The synovial fluid S/Neff on fat‐suppressed FSE short TE images, fat‐suppressed FSE long TE images, and fat‐suppressed three‐dimensional DEFT images showed similar values. Fat‐suppressed three‐dimensional DEFT images showed the highest fluid‐cartilage C/Neff of all sequences. All images showed fair to good agreement with arthroscopy (kappa, 0.615 in FSE short TE, 0.601 in FSE long TE, 0.583 in three‐dimensional SPGR, and 0.561 in three‐dimensional DEFT). Although the sensitivity of all sequences was high (100% in FSE short TE, FSE long TE, and DEFT; 96.7% in SPGR), specificity was relatively low (67.6% in FSE short TE and FSE long TE; 85.3% in SPGR; 58.3% in DEFT). The peripheral area of bone marrow edema or whole area of bone marrow edema on fat‐suppressed FSE images was demonstrated as low or iso‐signal intensity on fat‐suppressed three‐dimensional DEFT images.

Conclusion

Fat‐suppressed three‐dimensional SPGR imaging and fat‐suppressed FSE imaging showed high sensitivity and high negative predictive values, but relatively low specificity. The Kappa value and exact agreement was the highest on fat‐suppressed FSE short TE images. Fat‐suppressed three‐dimensional DEFT images showed results similar to the conventional sequences. J. Magn. Reson. Imaging 2004;20:857–864. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Chondromalacia of the knee: Evaluation w
✍ Jin-Suck Suh; Jae-Hyun Cho; Kyoo-Ho Shin; Sung Jae Kim 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 658 KB

## Abstract Twenty‐one MRI studies with a fat‐suppression three‐dimensional spoiled gradient‐recalled echo in a steady state (3D SPGR) pulse sequence after intravenous contrast injection were evaluated to assess the accuracy in depicting chondromalacia of the knee. On the basis of MR images, chondr

Repeatability of patellar cartilage thic
✍ Marcus Tieschky; Sonja Faber; Michael Haubner; Heiner Kolem; Erik Schulte; Karl- 📂 Article 📅 1997 🏛 Elsevier Science 🌐 English ⚖ 670 KB

A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distributi

Fat suppression gradient-echo magnetic r
✍ Kari Palosaari; Risto Ojala; Roberto Blanco-Sequeiros; Osmo Tervonen 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 716 KB

## Purpose: To evaluate the diagnostic performance of a newly developed single-scan phase-contrast water-fat imaging technique for fat suppression at 0.23t open magnet, compared to the conventional chemical shift selective fat suppression method at 1.5t, in the detection of experimental articular c