𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Magnetic resonance elastography of the kidneys: Feasibility and reproducibility in young healthy adults

✍ Scribed by Olivier Rouvière; Rémi Souchon; Gaële Pagnoux; Jean-Michel Ménager; Jean-Yves Chapelon


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
246 KB
Volume
34
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To evaluate the feasibility and reproducibility of renal magnetic resonance elastography (MRE) in young healthy volunteers.

Materials and Methods:

Ten volunteers underwent renal MRE twice at a 4–5 week interval. The vibrations (45 and 76 Hz) were generated by a speaker positioned beneath the volunteers' back and centered on their left kidney. For each frequency, three sagittal slices were acquired (eight phase offsets per cycle, motion‐encoding gradients successively positioned along the three directions of space). Shear velocity images were reconstructed using the curl operator combined with the local frequency estimation (LFE) algorithm.

Results:

The mean shear velocities measured in the renal parenchyma during the two examinations were not significantly different and exhibited a mean variation of 6% at 45 Hz and 76 Hz. The mean shear velocities in renal parenchyma were 2.21 ± 0.14 m/s at 45 Hz (shear modulus of 4.9 ± 0.5 kPa) and 3.07 ± 0.17 m/s at 76 Hz (9.4 ± 0.8 kPa, P < 0.01). The mean shear velocities in the renal cortex and medulla were respectively 2.19 ± 0.13 m/s and 2.32 ± 0.16 m/s at 45 Hz (P = 0.002) and 3.06 ± 0.16 m/s and 3.10 ± 0.22 m/s at 76 Hz (P = 0.13).

Conclusion:

Renal MRE was feasible and reproducible. Two independent measurements of shear velocities in the renal parenchyma of the same subjects showed an average variability of 6%. J. Magn. Reson. Imaging 2011;. ©2011 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Development and application of magnetic
✍ Mark M. Bahn; Michael D. Brennan; Rebecca S. Bahn; Diana S. Dean; Jennifer L. Ku 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 241 KB

## Abstract ## Purpose: To noninvasively assess the shear stiffness of the thyroid gland in vivo in order to determine whether magnetic resonance elastography (MRE) might hold clinical utility in the diagnosis of thyroid disease. ## Materials and Methods: Quantitative parametric images of thyroi

The influence of athletic activity on th
✍ Murat Uzel; Ercan Cetinus; H. Cetin Ekerbicer; Ahmet Karaoguz 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 91 KB

## Abstract ## __Purpose__ Complaints deriving from the plantar fascia are relatively common in athletes. This study aimed to investigate the changes of thickness of plantar fascia via sonography in healthy young adults with different levels of activity. ## __Patients and Methods__ One hundred t

Assessment of skeletal muscle perfusion
✍ Amelie M. Lutz; Dominik Weishaupt; Beatrice R. Amann-Vesti; Thomas Pfammatter; K 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB

## Abstract ## Purpose To probe the potential and pitfalls of contrast medium first‐pass skeletal muscle perfusion imaging under reproducible stress conditions. ## Materials and Methods Magnetic resonance (MR) signal dynamics in calf muscle and lower‐leg arteries of 20 healthy volunteers were an

Diffusion-weighted magnetic resonance im
✍ Daisuke Maki; Yuji Watanabe; Masako Nagayama; Takayoshi Ishimori; Akira Okumura; 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 312 KB 👁 2 views

## Abstract ## Purpose: To investigate the feasibility and usefulness of diffusion‐weighted magnetic resonance imaging in the detection of testicular torsion. ## Materials and Methods: Institutional Review Board approval and informed consent from all participants were obtained. Consecutive 28 pa