𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Lumbosacral nerve root stimulation comparing electrical with surface magnetic coil techniques

✍ Scribed by Dr. FRACP R. A. L. MacDonell; Dr. D. Cros; Dr. B. T. Shahani


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
448 KB
Volume
15
Category
Article
ISSN
0148-639X

No coin nor oath required. For personal study only.

✦ Synopsis


Stimulation of lumbosacral nerve roots using a monopolar needle electrode was compared with magnetic stimulation using a 7-cm diameter surface coil. Compound muscle action potentials were recorded from the tibialis anterior (TA) and flexor hallucis brevis (FHB) muscles. Although the mean latency of CMAPs did not differ using the two techniques, amplitudes were considerably larger using a needle. Mean amplitudes were 66% (TA) and 64% (FHB) of the direct M response obtained by distal, supramaximal stimulation compared with mean values using maximal magnetic coil stimulation of 36% (TA) and 25% (FHB). Minimum F-wave latencies from FHB were used to estimate the site of nerve root stimulation using both techniques. Although there was a large amount of variability in the data from individual subjects, the results suggested that, on the average, both forms of stimulation act proximal to the intervertebral foramen. We conclude that a needle electrode is a more suitable technique for stimulating lumbosacral nerve roots.