Low water to cement ratio concretes
β Scribed by Jan Skalny; J.C. Phillips; D.S. Cahn
- Publisher
- Elsevier Science
- Year
- 1973
- Tongue
- English
- Weight
- 592 KB
- Volume
- 3
- Category
- Article
- ISSN
- 0008-8846
No coin nor oath required. For personal study only.
β¦ Synopsis
Compressive andflexural strengths, dimensional changes, and freezethaw resistance of concretes made with low water to cement ratios were evaluated. In addition, exploratory studies of the rheological properties of low water content cement-aggregate-admixture systems were performed. The results indicate that, under well controlled conditions, workable concrete mixes can be obtained with w/c ratios as low as 0.28. Additionally, concretes having not only higher strength, but better freeze-thaw resistance and other engineering properties could be obtained. Unsolved problems connected with production of low water to cement ratio concretes are briefly discussed.
Druck-und Biegezugfestigkeit, Ausdehnungsverhalten und Frost-Tau-WechselbestSndigkeit von Betonen mit niedrigen Wasserzementwerten wurden ausgewertet. Vorl~ufige Untersuchungen von rheologischen Eigenschaften von Zement -Stein bzw. Sand -Zusatzmittel Systemen wurden auch ausgefUhrt. Es wurde gefunden dass, unter genau kontrollierten Bedingungen, bearbeitbare Frischbetonen mit W/Z Werten bis herunter zu 0.28 hergestellt werden k~nnen. Ferner, diese Betone haben nicht nur h~here Festigkeiten, sondern auch h~here Frostbest~ndigkeit und andere vorteilhafte Eigenschaften. Noch ungel6ste Probleme der Fertigung von Betonen mit niedrigen W/Z Werten werden kurz diskutiert.
π SIMILAR VOLUMES
Clinkers of nominal Czechoslovak production were ground in presence of grinding aid (d~rivative of lignin) to specific surfaces 400 -2700 m-/kg and were processed in presence of sodium Zignosulfonate and alkali carbonate (resp. bicarbonate) into pastes and mortars with low water-to-cement ratio. The
This paper outlines the findings of a study on the influence of cement content (275-425 kg/m) and water/cement ratio (0)45 to 0)75) on the durability of concrete exposed to silage effluent. The test facility exposed concrete specimens to a controlled flow of effluent such that the volume of effluent
Normal Portland cement concretes with a water-cement ratio of 0,3 and concretes containing 9% condensed silica fume (CSF) at a water-cementitious material ratio of 0,3 were submitted to freeze-thaw cycles in water in accordance with ASTM Standard C 666. The CSF concretes were also submitted to freez