✦ Synopsis


ABSTRA CT

The low frequency (below 150 Hz) acoustic ground impedance was determined on a large uncultivated field using an impedance meter, the probe microphone method, a modified Biot-Stoll type calculation, and the phase gradient method. The impedance measured with the impedance meter has lower real and imaginary parts than the impedance determined from the probe microphone measurements. The modified Biot-Stoll type description of acoustic to seismic transfer based upon seismic and acoustic measurements gives an impedance which is consistent with probe microphone measurements. The impedance measured by the phase gradient method is largely consistent with the other measurements, but shows much more structure. This structure is believed to be caused by unwanted reflections during the measurement procedure rather than by actual structure in the ground impedance undetected by the other methods.


πŸ“œ SIMILAR VOLUMES


Measurements of the normal acoustic impe
✍ P.J. Dickinson; P.E. Doak πŸ“‚ Article πŸ“… 1970 πŸ› Elsevier Science 🌐 English βš– 752 KB

This investigation was undertaken to provide some data on the sound absorption properties of ground surfaces and to develop a method for field measurement of the acoustic impedance of the ground surface. Initial tests with an impedance tube showed that although results were satisfactory for sand wit

Impedance measurement errors due to non-
✍ J.-P. Diard; B. Le Gorrec; C. Montella πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 679 KB

The effects of electrochemical systems non-linearities on impedance measurements with a Frequency Response Analyser have been investigated in low frequency domain from both a theoretical and experimental viewpoint. A theoretical expression for the polarization resistance measurement error has been f

A standing-wave facility for low-frequen
✍ George W. Swenson Jr πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 501 KB

The system consists of an enclosed waveguide operating in the fundamental mode, with an array of microphones and data processing electronics for determining the complex reflection coefficient of a surface two meters square.