𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Long-term evaluation of porous poly(ϵ-caprolactone-co-L-lactide) as a bone-filling material

✍ Scribed by Johanna Holmbom; Anders Södergård; Erika Ekholm; Matis Märtson; Asko Kuusilehto; Pekka Saukko; Risto Penttinen


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
613 KB
Volume
75A
Category
Article
ISSN
1549-3296

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Porous poly(ϵ‐caprolactone‐co‐L‐lactide) (P(CL‐co‐LA, wt % ca. 5/95) sponges were prepared, coated biomimetically with CaP/apatite, and implanted with noncoated control sponges into rat femur cortical defects and dorsal subcutaneous space. The implants were inspected histologically at 2, 4, and 33 weeks after the operation. All implants were filled with fibrovascular tissue within 4 weeks. The femur implants were partially ossified with compact bone, which in the CaP‐coated sponges was less mature and more fragmented. Approximately equal amounts of bone were observed in both types of implants. The polymer induced a mild inflammatory reaction with foreign body giant cells but no accumulation of fluid. Degradation of the polymer was slow; most of it was found intact at 33 weeks in histological samples. Nondegraded polymer seems to prevent complete ossification. Cultured osteoblasts proliferated well on apatite‐coated material, whereas only a few cells were seen on noncoated material. Thus CaP/apatite coating helped the attachment of osteoblasts in cell cultures but did not offer any advantage in bone formation over noncoated material in vivo. We conclude that a shorter degradation time of P(CL‐co‐LA) is needed to create an optimal implant. Furthermore, in vivo experiments seem to be necessary for the estimation of osteopromotive properties of a biomaterial. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005


📜 SIMILAR VOLUMES


Long term in vivo degradation and tissue
✍ Rafi Chapanian; Man Y. Tse; Stephen C. Pang; Brian G. Amsden 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 513 KB

## Abstract Long term __in vivo__ degradation, and tissue response to, cylindrical elastomers made of photo‐cross‐linked star‐poly(ε‐caprolactone‐__co__‐D,L‐lactide) triacrylate were investigated through subcutaneous implantation in rats. The elastomers were prepared via UV initiated crosslinking o

Long-term evaluation of functional nerve
✍ M.F. Meek; W.F.A. Den Dunnen; J.M. Schakenraad; P.H. Robinson 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 183 KB 👁 1 views

This study was performed to evaluate the long-term functional nerve recovery after reconstruction of a 10-mm gap in the sciatic nerve of the rat, with a thin-walled nerve guide, composed of a biodegradable copolymer of DL-lactide and -caprolactone [p(DLLA--CL)]. To evaluate both motor and sensory ne

The Use of Poly(L-lactide-co-caprolacton
✍ Pieter-Paul A. Vergroesen; Robert-Jan Kroeze; Marco N. Helder; Theodoor H. Smit 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 697 KB

## Abstract Since the early 1990s, tissue engineering has been heralded as a strategy that may solve problems associated with bone grafting procedures. The original concept of growing bone in the laboratory, however, has proven illusive due to biological, logistic, and regulatory problems. Fat‐deri

Development of a 95/5 poly(L-lactide-co-
✍ Rebecca Louise Simpson; Florencia Edith Wiria; Andrew A. Amis; Chee Kai Chua; Ka 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 495 KB

## Abstract 95/5 Poly(L‐lactide‐__co__‐glycolide) was investigated for the role of a porous scaffold, using the selective laser sintering (SLS) fabrication process, with powder sizes of 50–125 and 125–250 μm. SLS parameters of laser power, laser scan speed, and part bed temperature were altered and