The present research was conducted into the causes of and remedies for seawater corrosion in desalination plants. Several localized corrosion along structural steels and its weldments has occurred in fabricated structures, such as the shells of desalinators, which are exposed to corrosive environme
Localized corrosion behavior in stainless and structural steels weldments under desalination plant condition
β Scribed by H. Al-Zahrani; S. Somuah; N.M.A. Eid
- Publisher
- Elsevier Science
- Year
- 1991
- Tongue
- English
- Weight
- 34 KB
- Volume
- 84
- Category
- Article
- ISSN
- 0011-9164
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
In a previous instalment, the effect of surface roughness and type of welding electrode on localized corrosion at welds in structural steel under desalination plant conditions have been discussed. The present part deals with the effect of heat treatment, test temperature and test media.
In the recent past, the damage caused by rebar corrosion in concrete structures has been considered as one of the major durability problems affecting the service life of concrete structures. In order to prevent corrosion of steel reinforcement, various types of protective methods have been adopted.