𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Liquid chromatography–tandem mass spectroscopic method for the determination of zerumbone in human plasma and its application to pharmacokinetics

✍ Scribed by Eltayeb E. M. Eid; Ahmad Bustamam Abdul; A. Rasedee; Fakhr Eldin O. Suliman; Mohd A. Sukari; Safa A. Fatah


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
289 KB
Volume
46
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A rapid, sensitive, specific and selective LC–MS/MS method for the determination of zerumbone (ZER) in human plasma using 2,4‐diamino‐6‐(4‐methoxyphenyl)‐1,3,5‐triazine (DMTZ) as an internal standard (IS) has been developed and validated. ZER was chromatographed on C8 column using a mobile phase of acetonitrile/water (80:20, v/v) at a flow rate of 0.25 ml min^−1^. Quantitation was achieved using ESI+ interface, employing multiple reaction monitoring (MRM) mode at m/z 219 > 81 and 218 > 134 for ZER and IS, respectively. The calibration standards were linear over a range of 5–3000 ng ml^−1^ (r^2^ = 0.9994) with an LLOQ of 5 ng ml^−1^ (RSD %; 11.4% and bias%; 9.5%). Intra‐ and inter‐day precision of ZER assay ranged from 0.18 to 3.56% with accuracy (bias) that varied between − 5.09 and 4.3%, demonstrating good precision and accuracy. Recoveries of ZER and the IS from human plasma were above 85%. The developed method was validated for the determination of ZER in rat plasma. Linearity, stability of ZER and the ME on rat plasma were discussed. The applicability of the developed method was demonstrated by measuring ZER in rat plasma samples following intravenous and intraperitoneal administration of ZER prepared in hydroxypropyl‐β‐cyclodextrin (HPβCD) and sodium carboxymethyl cellulose (CMC), respectively, in 20 mg kg^−1^ and this study indicated a clear significant difference (p < 0.05) in pharmacokinetic parameters of ZER in ZER/HPβCD complex compared with ZER in CMC preparation. Copyright © 2011 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Liquid chromatography-tandem mass spectr
✍ Kamal M. Matar; Ahmed Z. El-Hashim; Ivan O. Edafiogho 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 305 KB

## Abstract A rapid LC‐MS/MS method for quantification of an enaminone analog, E121 in mouse plasma using E118 as an internal standard (IS) has been developed and validated. The analyte was analyzed on C~18~ column using a mobile phase of acetonitrile/methanol/ammonium acetate/formic acid (60:20:20

Determination of clopidogrel in human pl
✍ Beom Soo Shin; Sun Dong Yoo 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 369 KB 👁 2 views

## Abstract A rapid and sensitive LC/MS/MS assay was developed and validated for the determination of clopidogrel in human plasma. Clopidogrel was extracted by single liquid–liquid extraction with pentane, and chromatographic separations were achieved on a C~18~ column. The method was validated to