Abstract
A liquid chromatographic method for the determination of meloxicam in serum has been developed. The technique includes a solid phase extraction of the serum samples on [poly (divinylbenzeneco-N-vinylpyrrolidone)] as a solid phase extraction sorbent. After conditioning, the cartridge was loaded with 1 mL of acidified serum containing an internal standard. Elution was carried out using 1 mL of water-acetonitrile (Ο r = 1: 1) mixture. After evaporation of the eluate to dryness and reconstitution of the residue with 0.1 mL of methanol, the samples were analyzed on a Symmetry C18 column. Mobile phase consisted of 1 % aqueous acetic acid/THF/acetonitrile (Ο r = 60: 30: 10) + 0.1 mL of 1-octane sulfonic acid. Detection was carried out using a photodiode array detector. Full validation of the proposed method is provided. Linearity of the method was proven over the range of 0.01β10 Οg mLβ1 of meloxicam. Meloxicam assay was accurate and reliable with average intra- and inter-day precisions lower than 5.0 % and the intra- and inter-day accuracy higher than 97 %. Limits of detection (LOD) and quantitation (LOQ) found were 0.003 ΞΌg mLβ1 and 0.01 ΞΌg mLβ1, respectively. The proposed method was successfully utilized to quantify meloxicam in serum.