𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Left ventricular diastolic function assessment from three-dimensional three-directional velocity-encoded MRI with retrospective valve tracking

✍ Scribed by Anne Brandts; Matteo Bertini; Evert-Jan van Dijk; Victoria Delgado; Nina Ajmone Marsan; Rob J. van der Geest; Hans-Marc J. Siebelink; Albert de Roos; Jeroen J. Bax; Jos J.M. Westenberg


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
360 KB
Volume
33
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To compare parameters describing left ventricular (LV) diastolic function obtained with three‐dimensional (3D) three‐directional velocity‐encoded (VE) MRI with retrospective valve tracking and two‐dimensional (2D) one‐directional VE MRI in patients with ischemic heart failure. Second, to compare classification of LV diastolic function, and in particular for discriminating restrictive filling patterns, with both MRI techniques versus Doppler echocardiography.

Materials and Methods

The 3D and 2D VE MRI early (E) and atrial (A) peak flow rate indices, determined from transmitral waveform analyses, were compared. Also, net forward flow volume per cycle and transmitral regurgitation fraction were determined. Agreement in classifying diastolic filling patterns between 3D and 2D VE MRI versus Doppler echocardiography was evaluated using kappa statistics.

Results

The 3D three‐directional VE MRI with retrospective valve tracking was statistically significantly different from 2D one‐directional VE MRI for net forward flow volume and regurgitation fraction through the mitral valve and all parameters describing the diastolic waveform filling pattern, except for the E deceleration time and E/A filling ratio. Kappa‐agreement between 3D three‐directional VE MRI with retrospective valve tracking and echocardiography for classifying diastolic filling patterns was superior to 2D one‐directional VE MRI and echocardiography (i.e., κ = 0.91 versus κ = 0.79, respectively).

Conclusion

The 3D three‐directional VE MRI with retrospective valve tracking better describes LV diastolic function as compared to 2D one‐directional VE MRI in patients with ischemic heart failure. J. Magn. Reson. Imaging 2011;33:312–319. © 2011 Wiley‐Liss, Inc.