Laser ablation of dyed acrylic bone cement

✍ Scribed by Lee, Chi L.; Roberts, Cynthia; Litsky, Alan S.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
614 KB
Volume
20
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Revision surgery of cemented implants is indicated when mechanical failure causes severe pain and/or loss of function for the patient. Successful revision arthroplasty of cemented implants requires complete removal of the existing cement. Removal of old cement is an arduous task often causing damage to the surrounding bone tissue. In this study, the authors investigate the use of an Argon laser and the addition of dyes to enhance the laser ablation of bone cement. Methylene blue and red dye ΥΆ13 were each added separately to polymethylmethacrylate (PMMA) bone cement powder. A continuous wave Argon ion laser ( = 514 nm) was used for cement ablation. Cement samples were ablated at different power levels (1.5, 2.3, and 3.0 W) and exposure times (30, 60, 90, 120 sec). The results show that the Argon laser was unable to ablate undyed PMMA. However, the addition of either methylene blue or red dye ΥΆ13 greatly improved cement ablation by altering the cements' absorption characteristics. Results of Student's t-tests show a statistical difference between red and blue dyed PMMA mean ablation areas at all energy levels tested (P < .0002). As expected, all red ablation areas were greater than blue ablation areas at each energy level tested since red dye absorbs more energy at 514 nm than methylene blue dye. The results of this study suggest that by selectively altering the absorption characteristics of PMMA, laser removal of bone cement can be achieved. In addition, this study also shows that bone tissue does not absorb visible light energy at 514 nm, suggesting that bone cement may be removed with minimal damage to the surrounding bone tissue.


πŸ“œ SIMILAR VOLUMES


Degree of polymerization of acrylic bone
✍ Bayne, S. C. ;Lautenschlager, E. P. ;Compere, C. L. ;Wildes, R. πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 381 KB πŸ‘ 1 views

## Abstract Self‐curing poweder‐liquid admixed acrylic systems are used for internal fixation of total hip and total knee prostheses. Gel permeation chromatography revealed that the polymer chain length distributions of set cements were basically unaffected by their curing pressures. However, a dec

Physical characteristics of setting of a
✍ Lautenschlager, E. P. ;Moore, B. K. ;Schoenfeld, C. M. πŸ“‚ Article πŸ“… 1974 πŸ› John Wiley and Sons 🌐 English βš– 454 KB πŸ‘ 1 views

## Abstract An investigation was conducted to determine the general physical characteristics of self‐curing acrylic resin systems in terms of their potential utilization in total hip arthroplasty. Exothermic temperature, working and setting times were monitored with thermocouples placed in acrylic

Mechanical effects of erbium:YAG laser b
✍ Dr. Raimund Hibst πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 475 KB

When intending to use pulsed erbium:YAG laser radiation for the ablation of small bones, e.g., the ossicular chain or footplate, not only temperature and thermal damage, but also mechanical side effects become important. In studies on desiccated bone the total recoil momentum caused by laser ablatio