Large-volume sample on-line concentration of angiotensins in non-aqueous capillary electrophoresis
โ Scribed by Shinya Kitagawa; Akitsugu Noji; Naofumi Matsushita; Hiroyuki Nakagawa; Takahiro Asai; Hajime Ohitani
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 361 KB
- Volume
- 32
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
A single step onโline concentration and separation method for peptides in nonโaqueous capillary electrophoresis was developed. ACN containing 50โmM tetraethylammonium perchlorate was used as the electrophoretic medium; angiotensins IโIV were separated as a result of the differences in the magnitudes of their interactions with perchlorate anions. When the sample solution (ACN containing 0.5% trifluoroacetic acid and angiotensins) was injected as a largeโvolume plug, the analytes were concentrated at the inlet end of the capillary by both sweeping and stacking mechanisms; the separation procedure then started automatically without any operations such as polarity change. It was found that the concentration of analytes, injection period, and concentration of tetraethylammonium perchlorate in the electrophoretic medium were important factors for both separation and concentration efficiencies. The angiotensins were concentrated and separated with the largeโvolume injection of up to 80% of the effective capillary length.
๐ SIMILAR VOLUMES
## Abstract We present a new system for the sensitive analysis of cephalosporins by CE using both onโline SPE and largeโvolume sample stacking (LVSS). Sample volumes of 250โ ฮผL were loaded onto the SPE microcolumn which was then desorbed with 426โ nL of ACN. The SPE elution plug was injected into the
## Abstract Single drop microextraction (SDME) is a convenient and powerful preconcentration method for CE __before__ injection. By simple combination of sampleโhandling sequences without modification of the CE apparatus, a drop of an aqueous acceptor phase covered with a thin organic layer was for
High-ionic-strength samples result in poor electrophoretic separation efficiencies due to ''destacking'' of the sample. A simple method is described to stack high-ionic-strength samples without matrix modification prior to injection. Using a weak-acid buffer such as acetate as the background electro
In capillary electrophoresis, the short optical path length associated with on-column UV detection imposes an inherent detection problem. Detection limits can be improved using sample stacking. Recently, large-volume sample stacking (LVSS) without polarity switching was demonstrated to improve detec