Large-volume on-column injections for gas chromatography

✍ Scribed by Silvia Ramalho; Thomas Hankemeier; Marco de Jong; Udo A. Th. Brinkman; René J. J. Vreuls


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
941 KB
Volume
7
Category
Article
ISSN
1040-7685

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Large‐volume injection is an attractive means to improve detection limits when analyzing dilute sample extracts. There is now no need to achieve enrichment by means of solvent evaporation, which makes the total analytical procedure less reliable and less robust due to loss of volatile compounds. In this study on‐column injection was applied for large‐volume injection using an on‐column injector in combination with a deactivated uncoated fused silica capillary (retention gap) and an early solvent vapor exit. Two strategies are described. The first one relies on the programmable speed of an infusion pump, which is adapted such that it lies just above the evaporation rate of the extraction solvent used. With the second procedure, which can be used for a commercially available autosampler, the evaporation speed is adjusted to the fixed speed of injection by varying the temperature during injection. During optimization the additional solvent evaporation time was determined. The optimum conditions for an injection volume of 100 μL of either n‐hexane or ethyl acetate are reported. Large‐volume injection was used for simplified and miniaturized solid‐phase extraction procedures. The procedures were used to determine various organic micropollutants, such as organophosphorus pesticides and triazine herbicides, in tap and surface water extracts, using a flame photometric, and a mass spectrometric detector. For both methods good recovery for most of the analytes (70–87%), linear calibration curves (0.01‐5 μg/L range), and relative standard deviations of less than 10% were obtained. Detection limits typically were in the range of 1–10 ng/L for GC‐FPD and 10–150 ng/L for GC‐MS. When working in the time‐scheduled multiple ion detection mode detection limits in GC‐MS were one order of magnitude lower. © 1995 John Wiley & Sons, Inc.


📜 SIMILAR VOLUMES


An automated large volume on-column inje
✍ McCabe, T. ;Hiller, J. F. ;Morabito, P. L. 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 497 KB 👁 2 views

Automated large volume (25-200 1-11) on-column injections into a gas chromatograph with a capillary column were successfully performed by coupling a retention gap technique with an air actuated rotary valve. The linearity, injection precision, and carryover were evaluated. Slight boiling point discr

Large Volume Injection in Fast Gas Chrom
✍ Korytár, Peter ;Matisová, Eva ;Lefflerová, Henrieta ;Slobodník, Jaroslav 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 87 KB

In this work a fast gas chromatography set-up with on-column injection was optimized and evaluated with a model mixture of C 8 -C 28 nalkanes. Usual injection volumes when using narrow-bore (e. g., 0.1 mm i.d.) analytical columns are ca. 0.1 lL. The presented configuration allows introduction of 10

Direct injection on capillary columns fo
✍ Chauhan, J. ;Darbre, A. 📂 Article 📅 1981 🏛 John Wiley and Sons 🌐 English ⚖ 417 KB

## Abstract Discrimination may occur when injecting samples onto gas chromatography capillary columns, whereby peak areas for higher boiling point compounds are smaller than they should be compared to lower boiling compounds. This problem is most important in quantitative work on solutes having a w

Increased on-column injection temperatur
✍ Janák, Karel ;Colmsjö, Anders ;Östman, Conny 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract A way of controlling the maximum allowable oven temperature during on‐column injection by the column pressure drop is suggested. An arrangement using a restriction at the column outlet for adjustment of the column inlet pressure while maintaining the same column flow has been studied. C