𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Isometric strength measurements in children with arthritis: Reliability and relation to function

✍ Scribed by Wessel, Jean ;Kaup, Cara ;Fan, Jean ;Ehalt, Ross ;Ellsworth, Janet ;Speer, Coral ;Tenove, Pat ;Dombrosky, Allison


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
191 KB
Volume
12
Category
Article
ISSN
0004-3591

No coin nor oath required. For personal study only.

✦ Synopsis


Objective. To examine the reliability of testing strength in children with juvenile arthritis (JA), and to determine the relationship between strength and function.

Methods.

Children with JA were tested for grip and pinch strength (n Ο­ 32). Isometric force produced by hip abductors and knee extensors was tested with a hand-held dynamometer (n Ο­ 29). Two therapists both performed each of the tests twice so that intrarater and interrater reliability could be examined. Function was measured by means of the Childhood Health Assessment Questionnaire (CHAQ) and performance on a 50-meter run. Reliability was examined with intraclass correlations (ICC). The relationships of strength and function were determined with Pearson and Spearman correlations.

Results. All measures demonstrated good intrarater (ICC Ο­ 0.92-0.97) and interrater (ICC Ο­ 0.80 -0.95) reliability. Grip strength and pinch were correlated with the CHAQ (r Ο­ Οͺ0.45 and Οͺ0.33, respectively), while hip abduction and knee extension torque were correlated with rankings on the 50-meter run (rho Ο­ Οͺ0.34 and Οͺ0.38, respectively).

Conclusion. Isometric strength can be reliably measured in children with arthritis in a clinical setting.


πŸ“œ SIMILAR VOLUMES


A systematic review of instruments measu
✍ van der Leeden, Marike ;Steultjens, Martijn P. M. ;Terwee, Caroline B. ;Rosenbau πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 103 KB πŸ‘ 2 views

## Abstract ## Objective To compose an inventory of instruments that have been described to measure foot function (i.e., pressure and/or gait parameters), foot pain, and foot‐related disability in rheumatoid arthritis (RA), and to investigate the clinimetric quality of these measures. ## Methods

31P MRS measurement of mitochondrial fun
✍ D. Enette Larson-Meyer; Bradley R. Newcomer; Gary R. Hunter; Hoby P. Hetheringto πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 222 KB πŸ‘ 1 views

The reliability, relation to whole-body maximal oxygen uptake (VO(2max)), and force-level sensitivity of (31)P MRS markers of mitochondrial function were studied in 39 normal-weight women. Following 90 s isometric plantar-flexion exercises at 45, 70 and 100% of maximum voluntary contraction, skeleta

Clinical improvement as reflected in mea