๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Iowa's first electrodialysis reversal water treatment plant

โœ Scribed by John Hays


Book ID
104112660
Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
309 KB
Volume
132
Category
Article
ISSN
0011-9164

No coin nor oath required. For personal study only.

โœฆ Synopsis


In 1979 the City of Washington was notified by the Iowa Deparlment of Natural Resources (IDNR) that the City was in violation of the radium standard for drinking water. The City of Washington authorized an engineering study to determine the most cost-effective and practical way to remove radium and, at the same time, improve overall water quality. Several possible treatment alternatives were evaluated. It was finally decided to utilize electrodialysis reversal (EDR). Washington obtains its water from three deep wells ranging in capacity from 600-780 gpm. The untreated water withdrawn from the wells first passes through the EDR traits. There are three EDR units, each able to produce 285 gpm of finished water. In the future, another EDR unit can be easily added to the other three units, since the new plant was built and plumbed for an additional EDR unit if water demand increased. The Jordan aquifer supply is adequate for current and future needs. The average daily water usage in 1993 was 818,000 gal/d. In order to meet peak flows, it is possible to bypass the EDR units with part of the untreated water and then blend treated and untreated water. The treated water meets IDNR standards of 5.0 pC/L. After the EDR units, the water flows through an aerator where odor-causing gases and carbon dioxide are removed. Aeration reduces the amount of caustic soda and chlorine used in the finished water. The hydrogen sulfide gas leaves the water as it passes through the aerator, and this loss of gas creates less chlorine demand. Total and free chlorine residuals are now detected in every water main of the town, whereas before, the residuals would not be detected in certain area of Washington. Phosphates have been cut back from 7 pounds per day to one pound per day. Better water quality is now being achieved with fewer chemicals added to the finished water. Washington's water treatment plant is the first municipal EDR plant in the State of Iowa and one of the largest municipal installations in the United States.


๐Ÿ“œ SIMILAR VOLUMES


Performance of the first sea water elect
โœ P.K. Narayanan; S.K. Thampy; N.J. Dave; D.K. Chauhan; B.S. Makwana; S.K. Adhikar ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 713 KB

The problem of potable water shortage in some of the islands and coastal areas of India has led to consider sea water desalination for potable purposes . One of the membrane processes, namely, the electrodialysis(ED) has been designed and fabricated to meet the demand of a section of the population

Grameen-Veolia Water inaugurates first w
๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 81 KB

Black & Veatch will design and oversee construction of the project which will more than triple the water treatment works' capacity. The project involves constructing additional water treatment facilities, increasing the pumping capacities of the secondary raw and fresh water pumping stations and sto