## Abstract Thirty magnetic resonance (MR)‐guided biopsies were obtained from 20 skeletal and 10 soft‐tissue lesions in 31 patients using an open 0.2 T MR system equipped with interventional accessories. The results from aspiration (__N__ = 3), core biopsy (__N__ = 15), and transcortical trephine b
Invited. MRI-guided biopsy of bone in a hybrid system
✍ Scribed by Joerg-Michael Neuerburg; Gerhard Adam; Arno Buecker; Karl W. Zilkens; Thomas Schmitz-Rode; David Hunter; Joop J. van Vaals; Rolf W. Guenther
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 726 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
This is a report of our experience with percutaneous, MRI‐guided biopsies in 25 patients with skeletal lesions using a 1.5‐T MR hybrid system. Twenty‐five consecutive patients with skeletal lesions were referred for MRI‐guided biopsy. Biopsies were performed with a 1.5‐T Philips Gyroscan (Philips Medical Systems, Best, The Netherlands) combined with a c‐arm fluoroscopy. Specimens were obtained percutaneously either with a 14‐ or 18‐gauge “side‐slit” type of biopsy needle (n = 10 skeletal lesions that had penetrated through the cortex), or using a prototype coaxial drill system powered either by hand or an optional motor (n = 15 skeletal lesions still covered with cortical bone). All but two biopsies could be completed within the MR unit. For one patient, who required a transpedicular approach to a lumbar vertebra, and for one child, who required general anesthesia, we decided to switch to CT guidance. In 19 of the 25 cases (17 of the 23 cases performed in MR), the sample was sufficient and the histopathologic diagnosis was confirmed. Three patients had an inadequate sample, and three others had adequate samples but inaccurate results. No procedural complications occurred. Percutaneous biopsy of skeletal lesions performed under MRI‐guidance was found to be safe and reasonably accurate. There were no procedural complications in our small series. MRI may be used as an alternative to CT, but its role vis‐à‐vis CT has yet to be ascertained.
📜 SIMILAR VOLUMES
The purpose of this study was the application of the proton-resonance-frequency method to monitor laser-induced interstitial thermotherapy (LITT) in a patient with an astrocytoma WHO II. A phase-sensitive two-dimensional (2D) fast low-angle shot (FLASH) sequence was used to determine the temperature
## Abstract ## Purpose: To present the clinical setup and workflow of a robotic assistance system for image‐guided interventions in a conventional magnetic resonance imaging (MRI) environment and to report our preliminary clinical experience with percutaneous biopsies in various body regions. ##
A fluorescence in situ hybridization (FISH) study was performed on trephine biopsies of the bone marrow in chronic myelogenous leukaemia (CML) to evaluate the bcr/abl translocation in macrophages before and during interferon (IFN) therapy. Mature macrophages and osteoclasts were identified by the mo
## Abstract Relaxation times (T~1~ and T~2~) of the bone marrow protons and trabecular bone volume fraction (TBVF) in the calcaneus were measured for 100 female volunteers using a compact MRI system at 0.2 T field strength. The speed of sound (SOS) through the calcaneus was measured also for the sa