✦ Synopsis


of the unit can be selected so that only pressure drops or surges greater than a preset minimum are recorded; this minimum can be set at between 10 and 400 mbar.

Advanced data compression allows up to two million readings to be stored by TAS, representing 48 hours continuous sampling at 10 samples/set.

Once testing is complete, data is downloaded onto a PC via an RS232C interface. TAS software allows for tabular, gra phical display in a Windows environment.

TAS is self contained, portable and housed in a ruggedised IP68 cast aluminium enclosure: total weight is 3.6 kg. The unit is submersible and powered by a built-in replaceable battery with a life expectancy of five years in normal operation.


πŸ“œ SIMILAR VOLUMES


Rotary lobe pumps
πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 498 KB

## Rotary lobe pumps are widely used rotary positive displacement pumps that find use in many applications. Here we feature some of the design aspects that have been developed recently and we look at the application of these pumps in challenging pumping duties. Ease of maintenance with unique fea

New rotary lobe pumps
πŸ“‚ Article πŸ“… 2003 πŸ› Elsevier Science 🌐 English βš– 279 KB
Pulsation problems in rotary lobe pumps
✍ H Vogelsang; B VerhΓΌlsdonk; M TΓΌrk; G HΓΆrnig πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 559 KB

With the Internet Pump Selection Program SPAIr-Onllne you will be able to make your latest products available to your customers world-wide. This can take place from the very start of production and if you want even earlier. Comprehensive information on: www.vsx. de