Intravascular ultrasound identification of stent entrapment in vivo with in vitro confirmation

✍ Scribed by Hiro, Takafumi ;Leung, Cyril Y. ;Russo, Robert J. ;Teirstein, Paul ;Yeatman, Lawrence A. ;Tobis, Jonathan M.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
313 KB
Volume
40
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


Objectives: One potential complication of stenting is ''stent jail'' due to placement of a stent across a side branch, which may impede additional interventions. Another form of stent entrapment may occur if the guidewire is accidentally withdrawn and then unknowingly passes through a stent loop during reentry with subsequent high pressure expansion. The purpose of this study was to evaluate this form of stent entrapment in vitro by intravascular ultrasound (IVUS). Methods: A guidewire was passed through the end or middle diamonds of Palmaz-Schatz and Palmaz stents or the middle of Gianturco-Roubin stents. A 3.5 mm balloon was inflated over the guidewire through the various side holes of the stents. Results: IVUS images presented three distinct patterns depending on the type of stent and position of balloon entry: 1) external compression and loss of wall continuity in the Palmaz-Schatz and Palmaz stents, 2) displacement of the side diamond across the lumen, and 3) external compression of the Gianturco-Roubin stent. The first and second patterns but not the third one were associated with impairment of lumen access. Conclusions: Based upon this in vitro verification, IVUS imaging can be used to identify the presence of stent entrapment in vivo.


πŸ“œ SIMILAR VOLUMES


Analysis of reproducibility of reference
✍ Kearney, Peter P. ;Ramo, M. Pauliina ;Shaw, T. R. D. ;Starkey, Ian R. ;McMurray, πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 40 KB πŸ‘ 2 views

Intravascular ultrasound is widely used to guide coronary stent implantation. The key quantitative criterion for successful implantation is the demonstration of adequate expansion of the stented lumen relative to that of the adjacent reference vessel segments. In this study we aimed to establish the

Intravascular ultrasound and quantitativ
✍ Francesco Prati; Tomasz Pawlowski; Luigi Sommariva; Antonella Labellarte; Alessa πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 120 KB

## Abstract Quantitative coronary angiography (QCA) is routinely used for assessment of strategies aimed at reducing in‐stent restenosis. Yet QCA enables only the measurement of luminal variation of stented segments and, unlike intravascular ultrasound (IVUS), provides only an indirect estimation o