๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Intraoperative localization of the sentinel node in breast cancer: Technical aspects of lymphoscintigraphic methods

โœ Scribed by Concetta De Cicco; Marco Chinol; Giovanni Paganelli


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
77 KB
Volume
15
Category
Article
ISSN
8756-0437

No coin nor oath required. For personal study only.

โœฆ Synopsis


Axillary lymph node dissection is an important part of the surgical treatment of breast cancer as a staging procedure. Recent progressive advances in early detection have led to the treatment of small primary carcinomas; thus, a great number of axillary dissections show completely negative lymph nodes. The sentinel node (SN) concept, developed for melanoma patients, seems to be similarly valid in breast cancer and has the potential to change the standard surgical approach in these patients. To verify the accuracy of lymphoscintigraphic method associated with radioguided biopsy of the sentinel node in a large series of patients, we studied 382 patients with operable breast cancer. Lymphoscintigraphy (LS) was performed the day before surgery; three different-sized ranges of 99mTechnetium-labeled colloid particles were injected either by subdermal or peritumoral administration. Planar scans were registred in anterior and oblique projections, and a cutaneous marker was placed over the skin corresponding to the SN as visualized. SNs were localized and removed during surgery, using a gamma-detecting probe (GDP); total axillary dissection was then performed. In 54 patients, blue dye was also administrated in the tumor bed immediately after excision of the primary. LS identified at least one SN in 377 of 382 cases (98.7%). Axillary SN was localized in 371 cases (97.1%). The overall concordance between SN status and other axillary nodes was 96.8% (359 of 371). Localization of the SN was easier when large-size particles of colloidal albumin were injected in a volume of 0.4 ml. GDP successfully localized SN in 54/54 cases (100%), while blue dye identified SN in 37/54 patients (68.5%). In 33 of 37 cases (89%) the dye and LS identified the same node. LS and GDP-guided surgery provide accurate identification and removal of the SN, particularly when large-size radiolabeled colloids are injected in a small volume. Semin.


๐Ÿ“œ SIMILAR VOLUMES


Combination technique is superior to dye
โœ Kazuyoshi Motomura; Hideo Inaji; Yoshifumi Komoike; Yoshihisa Hasegawa; Tsutomu ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 298 KB ๐Ÿ‘ 2 views

## Background: The purpose of the present study was to evaluate whether the combination of dye and radioisotope would improve the detection rate of sentinel nodes (sn) and the diagnostic accuracy of axillary lymph node status over dye alone in patients with breast cancer. ## Methods: Sentinel nod

Reverse transcription-polymerase chain r
โœ Michela Manzotti; Patrizia Dell'Orto; Patrick Maisonneuve; Stefano Zurrida; Giov ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ French โš– 59 KB ๐Ÿ‘ 1 views

The identification of specific tumor mRNA markers by reverse transcription-polymerase chain reaction might be a valuable diagnostic adjunct for the detection of breast cancer metastases in axillary sentinel lymph nodes (SLNs). In this study we have compared the diagnostic accuracy of an extensive hi

Sentinel lymph node mapping opens a new
โœ Giuseppe Canavese; Marco Gipponi; Alessandra Catturich; Carmine Di Somma; Carlo ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 45 KB ๐Ÿ‘ 2 views

Recent studies have demonstrated the possibility of identifying the sentinel lymph node (sN) as a reliable predictor of axillary lymph node status in both cutaneous melanoma and breast cancer. However, some important issues need further definition: (1) optimization of the technique for intraoperativ