Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions
✍ Scribed by Toshifumi Kamiryo; Yasuhiro Fujii; Masahiko Kusaka; Shiro Kashiwagi; Haruhide Ito
- Publisher
- Springer
- Year
- 1991
- Tongue
- English
- Weight
- 316 KB
- Volume
- 7
- Category
- Article
- ISSN
- 0256-7040
No coin nor oath required. For personal study only.
✦ Synopsis
A case of hydrocephalus showing slit ventricle syndrome after multiple shunt revisions was treated with a programmable pressure valve, and intracranial pressure was monitored with a telemetric sensor. High pressure setting produced positive and normal values of intracranial pressure in this patient. We report our experiences.