Abstract Survival, encephalopathy and shunt patency were studied in 64 consecutive patients who underwent mesocaval shunting with a wide-calibre Dacron® prosthesis. Half of the patients were operated as emergency cases. Operative blood loss in patients who had emergency procedures was significantly
✦ LIBER ✦
Interposition teflon mesenteric caval shunt for bleeding oesophageal varices
✍ Scribed by G. R. Giles; T. G. Brennan; M. S. Losowsky
- Publisher
- John Wiley and Sons
- Year
- 1973
- Tongue
- English
- Weight
- 483 KB
- Volume
- 60
- Category
- Article
- ISSN
- 0007-1323
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A modified mesenteric caval shunt using a Teflon ‘H’ prosthesis has been performed in 4 poor-risk patients with cirrhosis and exsanguinating haemorrhage from oesophageal varices and a fifth patient with portal vein thrombosis. Although 2 patients ultimately died, the procedure was effective in arresting the haemorrhage and is technically simple to perform.