Ab experunental techmque developed by Chavane and Grace has been used to measure Interphase mass transfer rates for bubbles m a two-dlmenslonal flmdlzed bed with different sizes of parkles from 90 to 39Opm It IS shown that the overall transfer rate, corrected for bubble growth and with neghsble effe
Interphase mass transfer in a gas fluidized bed
โ Scribed by C. Chavarie; J.R. Grace
- Publisher
- Elsevier Science
- Year
- 1976
- Tongue
- English
- Weight
- 824 KB
- Volume
- 31
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
โฆ Synopsis
Mass transfer rates have been measured for bubbles containing ozone injected into an air-fluidized two-dimensional bed of particles. The overall mass transfer coefficient, corrected for unsteady bubble growth effects and with entrance effects eliminated, lies between predictions of models which assume that throughflow and diffusion are both additive and rate-controlling and those models which assume that mass transfer is governed by diffusion at the cloud boundary. The experimental value is consistent with a model which bases mass transfer purely on the throughflow predicted by Murray. Failure to account for bubble growth leads to drastic overestimation of the mass transfer coefficient.
๐ SIMILAR VOLUMES
## Abstrac -A non-interfering technique has been used to measure the concentration of ozon: in pairs of bubbles injected into a bed of inactive 390 pm glass beads fluidized by ozone-free air. The transfer of the ozone tracer from the bubble phase to the dense phase is enhanced when compared to the